27
Programable inputs PI1 and PI 2
PI 1: Emergency / Fire alarm
The PI 1 input is , by default, programed as an emergency or fire alarm input. Every pulse of this input runs the door to
open position. This signal is programed by default as a continuous signal and NO ( normally open). If required it can be
programed as pulse signal an NC ( normally closed).
PI 2: Panic breakout
The PI 2 input is , by default, programed as a panic breakout input for panic breakout frames. The magnetic contact of
the profile has to be connected to this input. When the magnetic contact is opened the door will go to the open position
and remain open until the signal of the magnetic contact changes.
Programable outputs PO1 and PO 2
PO 1: Error signal
The PO 1 output, give a signal or switch on the output relay every time any error is come off. It´s possible to connect this
input to any device to control the door remotely.
PO 2: Door open or opening signal
The PO 2 output, give a signal or switch on the relay when the door is opened or opening. It´s a suitable output to
connect a buzzer or any sound signal to know the door is opening.