Fig. 12
Remove the power before to pick - up the
protection plexiglass and operate on the
terminal blocks.
5 - TIMER SETTING
6 - TRANSMITTER CODES MEMORISATION
6
5
4
3
2
1
ON
PR
LR
PV
LV
ON
1 2 3 4 5 6
OFF
Fig. 14
Pag. 8
3
-Connect the accessories as follows (fig. 6):
- if you want to use an antenna,( not supplied), connect the
shield to the terminal 10 and the net to the terminal 9,
otherwise if you use the antenna cable supplied, connect it to
the terminal 9.
- if you want to connect an external command device (not
supplied), connect the N.O. contact to the terminals 7 and
8.
7
9
8
10
Contact
Antenna
FUSE
The supplied 10 A fuse is calculated for the protection of loads
with 2000 W.
For lower power loads, it is advisable to adapt the fuse to the used
power, by using the following formula:
Max fuse current = (power in W of the load to drive ) / (supply
voltage of 230V)
Example:
For the command of a 500 W light, it will be necessary a fuse of:
500/230 = 2,17 A
Use then a fuse of 2,5A.
The timing can be set by means of a binary 8 way dip-switch ( Fig. 8)
If all dip-switches are positioned on OFF the temporisation is
excluded and the receiver operates in ON/OFF mode.
If at least one of the dip is in ON position, the temporisation is active.
This means that after a switching-on performed by radiocommand,
the switching off will occur after a time delay.
The dip-switch N°8 allows to multiply by 60 the time value set by
the dip-switches 1-7
In this way, it is possible to calculate the set up timing according
the following table:
Switch 8 at OFF
Switch 1 at ON = 10 sec.
Switch 2 at ON = 20 sec.
Switch 3 at ON = 40 sec.
Switch 4 at ON = 1 min.
Switch 5 at ON = 2 min.
Switch 6 at ON = 4 min.
Switch 7 at ON = 8 min.
Switch 8
at
ON
Switch 1 at ON = 10 min.
Switch 2 at ON = 20 min.
Switch 3 at ON = 40 min.
Switch 4 at ON = 1 h.
Switch 5 at ON = 2 h.
Switch 6 at ON = 4 h.
Switch 7 at ON = 8 h.
NOTE : If more then one dip is positioned at ON, the resulting time
become the sum of each single time.
Example:
Temporisation of 50 Sec.
switches at ON : 1, 3
switches at OFF : 2,4,5,6,7,8.
5
4
3
2
1
ON
6 7 8
OFF
ON
1 2 3 4 5
7
6
8
5
4
3
2
1
ON
6 7 8
OFF
ON
1 2 3 4 5
7
6
8
5
4
3
2
1
ON
6 7 8
OFF
ON
1 2 3 4 5
7
6
8
5
4
3
2
1
ON
6 7 8
OFF
ON
Temporisation
1 2 3 4 5
7
6
8
Fig.8
TX Memorisation
The method for the TX memorisation operates in
selflearning mode.
Push and keep pushed the button PR until the red led turns on; release
the button and press within 4 seconds the button of the transmitter to
memorise; the red led LR will turn off and the relay will exite for a while
to confirm the successfully operation.