background image

 

 

OPERATING INSTRUCTIONS 

  

Dust Extractor  

 

T7500 
T8600

READ ALL INSTRUCTIONS 

BEFORE USING 

Summary of Contents for T7500

Page 1: ...OPERATING INSTRUCTIONS Dust Extractor T7500 T8600 READ ALL INSTRUCTIONS BEFORE USING ...

Page 2: ...nue to supply the market with new equipment Notice These instructions are only for the dust extractors T7500 T8600 The dust extractors T7500 T8600 can only be used with dry non explosive material Ermator will not be held responsible if the air cleaner is used for other applications or has been used in ways other than those outlined in this instruction manual Before using the machine please read th...

Page 3: ...njury Warning Make sure the assembly area is firm so the dust extractor does not tip over Risk of personal and material injury Warning Risk of pinching when handling the toggle fastener Warning The machine must not be used in environments where explosive gases may be present Serious risk of explosion Service Warning Remove the plug from the wall socket when carrying out maintenance work Risk of pe...

Page 4: ... slowly Repeat this procedure 5 10 times If suction remains poor the filter should be replaced The plastic bag may only be replaced after cleaning the filter The plastic bag must be tied up after removal Only use original parts Filter change Risk of dust dispersion Use of personal safety equipment Unhealthy dust can be spread during filter change Accordingly the user should wear protective glasses...

Page 5: ...cription No machine 200600596 Complete filter set 1 pc 200600595 MF5500 HEPA filter 2 pcs 1337032 Cleaning set 1 pc 1376013 Longopac 4 pcs 1 pc For other spare parts see the enclosed spare parts list Warranty All Ermator devices and accessories have a 12 month factory warranty for material and manufacturing defects The warranty extends to 36 months when returning the attached warranty slip Do not ...

Page 6: ...se Procedure Motor does not start No power Connect the machine Switch defective Change Motor stops immediately Wrong fuse Connect the correct fuse Motor runs but there is Hose not connected Connect the hose no suction Hose blocked Clean the hose No plastic bag Install plastic bag Motor runs but suction is poor Damage to the hose Change hose Blocked filter Change filter Top cover loose Adjust Dirt ...

Page 7: ...3 353 MAX VACUUM H2O Inch 110 110 HOSE 33 feet x 3 33 feet x 3 INLET 3 3 FINE FILTER 99 5 99 5 Filter area 25 ft2 Filter aere 25 ft2 HEPA FILTER HEPA H13 HEPA H13 Filter area 54 ft2 Filter area 54 ft2 SOUND LEVEL 74 dB A 74 dB A DUST COLLECTION SYSTEM Longopac Longopac DIMENSION LxWxH 49x27x69 in 49x27x69 in WEIGHT 417 lbs 417 lbs ...

Page 8: ...0 Nr No 0700492c0001 xxxx T8600 Nr No 0600403a0001 xxxx Tillv år Manufact year Baujahr 2006 som omfattas av denna försäkring är i överensstämmelse med standarder included in this declaration follows the provisions of the est conforme aux aux normes suivantes den folgenden Normen entspricht er i overensstemmelse med standarder SS EN 292 1 SS EN 60 204 1 1993 11 30 SS EN 55011 1989 SS EN 50082 1 SS ...

Page 9: ...Revision 3 8 Exploded view T7500 T7500 T8600 ...

Page 10: ...c 22 1 200600536 Holder for longopac 23 1 200600716 Cover filter holder 24 2 200600605 HEPA filter kit 25 1 200600715 HEPA filter holder 26 1 1262009 Electrical box 7 5kW 230V 60HZ 27 1 200600718 Fan hold complete 28 1 200600717 Cover complete 29 1 200600712 Sweep complete 30 1 200600714 Back cover complete 31 1 200600713 Exhaust plate complete 32 1 200900046 SCA40 750T FAN 3x208V 33 2 25320 Wheel...

Page 11: ..._______ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ...

Page 12: ...Revision 3 11 ...

Reviews: