# VSH400PLC090909
- 17 -
3. Move the body (1) so as the horizontal axis of the locating insert (2) covers
with the table top surface (5) [Fig.26]. For levelling, it is recommended to use
the straight piece of bus of length approximately 1.5 m.
4. Holding the immobilized body on the panel press the pushbutton H >0< at the
height of the counter H
5. Return to the basic screen of the panel by taking out the locating insert (2) or
the offset insert (3) [Fig.26]
6. Check whether the hole is correctly made with the proper distance from the
edge of the bus
7. If necessary, scale the system of the counter H again
8. TECHNOLOGY
8.1 DIE BLANKING
NOTES:
When punching holes in aluminium rails, lubricate the punch with oil or
kerosene each time. Recommended agent: HHS 2000 manufactured by
WÜRTH.
Fig.23
8.1.1 ROUND HOLES
Prepare the station as described in 6.1
busbar
setting mandrel
stamp + spring