ELECTRONIC CONTROL PANEL
Page 9
PROGRAMMING INSTRUCTIONS -
CONFIGURATION PARAMETERS
All configuration parameters on this appliance have
been pre-programmed in the factory, to offer optimal
performance in a wide range of applications and situations.
See table at the end of this manual for default configuration
parameter settings.
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1.
Press the
scroll
button and hold it for 6 sec until the
display shows:
2.
Within 10 sec, press the
up
button; the display will
show:
•
Press the
up
or
down
button to set
the units of
measure (Metric or US)
.
3.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to
activate the
maintenance reminder function by setting the
maintenance interval, or deactivate the maintenance
reminder function
.
4.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to set
the
exchange capacity per litre of resin
.
5.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to set
the age
correction factor (%/year)
to compensate for capacity
loss of the resin due to aging.
6.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to set
the volume
of resin
.
7.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to set
the number
of days between regenerations
.
8.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to set
the length
of the regeneration cycle
.
•
Press the
scroll
button again to advance to the next
regeneration cycle.
Eco
Refill
Cycle 1
Brine preparation
Cycle 2
Backwash
Cycle 3
Brine draw/slow rinse
Cycle 4
Fast rinse
Cycle 5
9.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to set
the
regeneration mode
:
−
Dlyd/Immd
: when the remaining capacity equals
the reserve capacity, a
delayed regeneration
is
started at the programmed time of regeneration;
however when the remaining capacity equals 0
before the programmed time of regeneration is
reached, an
immediate regeneration
is started.
−
Immediate
: when the remaining capacity equals
0, an
immediate regeneration
is started.
−
Delayed
: when the remaining capacity equals the
reserve capacity, a
delayed regeneration
is
started.
10.
Press the
scroll
button again; the display will show
(only when the regeneration mode was set to 'Delayed' or
'Dlyd/Immd'):
•
Press the
up
or
down
button to set
the time of
regeneration
.
11.
Press the
scroll
button again; the display will show:
•
Press the
up
or
down
button to
activate or
deactivate the salt level alarm function
.
Cycle 1:
XXX
sec
System Check
Regen @
2:00
Units:
Metric
Resin:
XXX
liters
Age corr.:
1.0
%
Override: 7
days
Regen:Dlyd/Immd
Salt alarm:
ON
ExCap:
5.1
°f M3/L
MaintInt:
24
mths