TECHNICAL DATA
Page 25
Technical specifications:
Model
IQ-CS
Resin (Ltr)
9
12
18
26
Operating pressure min/max (bar)
1,4/8,3
Operating temperature min/max (°C)
2/48
Electrical connection
100-230/24VDC - 50/60Hz
(1)
Maximum power consumption (VA)
6,5
Hydraulic connection inlet/outlet
¾” BSP Male
(1)
Supplied with 24VDC transformer
Performances @ 3 bar operating pressure
(2)
:
(2)
Indicative numbers, performances depending on operating conditions and water quality
(3)
Flow rate at which softening process is still executed adequately
(4)
Maximum salt/water usage as brining is proportional (minimum of 40%)
Dimensions & weights:
Model
IQ-CS
Resin (Ltr)
9
12
18
26
Width (mm) (W)
280
Height (mm) (H)
497
575
728
982
Depth (mm) (D)
438
Depth, including bypass (mm)
540
Height inlet/outlet (mm)
375
453
606
860
Height inlet/outlet, including bypass (mm)
381
459
612
866
Weight (kg)
15,5
20,0
26,5
36,0
Weight, including bypass (kg)
16,0
20,5
27,0
36,5
Maximum salt storage capacity (kg)
13
17
23
35
Model
IQ-CS
Resin (Ltr)
9
12
18
26
Nominal exchange capacity (m³x°f)
32
54
92
133
Nominal exchange capacity (m³x°d)
18
30
52
74
Service flow rate @
∆p 1 bar
(m³/hr)
2,4
2,2
2,1
1,8
Recommended maximum service flow rate (m³/hr)
(3)
0,9
1,2
1,8
2,6
Salt usage per regeneration min/max (kg)
(4)
0,45/1,13
0,60/1,50
0,90/2,25
1,30/3,25
Rinse water usage per regeneration (Ltr)
(4)
47
58
81
121