Procedure
P014491C
Figure 65
Cable Secured
11. Make a note of the cable data on the cover of the OVP Module.
12. Reinsert the six screws in the DF and tighten them with a T30 Torx
screwdriver.
3.10
Connecting the Ericsson GPS Solution
To install the Ericsson GPS Solution, see the following:
GPS Solution Synchronisation, WCDMA, EN/LZT 735 0028.
3.11
Connecting RF Cables
Several antenna connections are possible, depending on the cell configuration,
Filter Unit (FU) type, and so on. For information about antenna connections to
the RBS cabinet, see the Site Installation Documentation.
Note:
All earth grounding of RF cables must comply with the instructions in
Grounding Guidelines for RBS Sites. In addition, the MET must be
positioned as close as possible to the cabinet, and the total length of
the earth grounding system from the RF cables through the MET to the
earth grounding point of the cabinet must not exceed 2 meters.
To connect the Radio Frequency (RF) cables between the antenna system
and the RBS 3107 do the following:
1.
Remove the two cable inlet parts.
53
1/1531-COH 109 2073 Uen H 2006-11-06
All manuals and user guides at all-guides.com