
Procedure
Figure 57
Cable Connections
5.
Make a note of the cable data on the cover of the OVP Module.
6.
Reinsert the six screws in the DF and tighten them with a T30 Torx
screwdriver.
3.7.4
Connecting Transmission Cables, Fiber Optic - Alternative 4
Note:
Handle the fiber optic cables with care and do not exceed the minimum
bending radius of 35 mm.
1.
Ensure that the DF is not fastened in place, and that the space beneath
it is accessible.
2.
Remove the rubber sealing in the DF cable entry closest to the OVP
module to be used.
3.
Remove the end nut from the fixed cable gland on the fiber optic cable and
pass the cable through one the of cable inlets as shown in the figure above.
4.
Remove the rubber sealing from the cable entry to be used.
5.
Insert the cable gland in of the DF cable entry as shown in the figure above.
6.
Reattach the nut and tighten it, using a 26 mm open-ended wrench.
47
1/1531-COH 109 2073 Uen H 2006-11-06
All manuals and user guides at all-guides.com
all-guides.com