Commercial in confidence 

 
 

7.4.1 

Remote fault handling 

Via SNMP O&M the Gateway 5780 unit can be accessed for fault analysis and 
trouble shooting. 

Examples of supported trouble shooting functionality: 

  Operational state 

  Alarm state 

  Local logs 

7.4.2 

LED handling  

Three LEDs indicating current operational state of the Gateway 5780. All 
operational states are also available via SNMP. It is possible to disable LED 
via management if wanted. Note that power on will always enable LED, but if 
LED is disabled, the LED will follow the current settings after restart, enabled, 
or disabled. 

 

Figure 20, LED display 

 

Red

 color indicates a major fault. It is used to show that there is a fault that 

must be handled on this unit.  

 

Green

 

color indicates normal operation. I.e. is used for LEDs that will be lit 

when the Gateway 5780 is working normally.  

 

Blue

 

color indicates a warning. It is used to show that something, (a unit or 

the Node), is not working correctly.  

LED start up sequence 

  At power on all LEDs will be turned on for 1 s.  

  Fault LED and Maintenance LED will be turned off (i.e. 1 s from start) 

  Operation LED will flash fast during software load 

  Operation LED will flash slowly after software load (~0.5 Hz) until network 

connection is established. (i.e. successful backhaul connection) 

  Operational LED will be steady on when Successful start and Gateway 

5780 is operational.

 

 

Summary of Contents for 5780

Page 1: ...Unlicensed LPWA Gateway 5780 Technical information USER GUIDE 1 1553 KRC 161 673 UEN Rev PB9 ...

Page 2: ...tallation 17 6 2 Pole Installation for Wall plate and Support 23 6 3 Install Support 6501 24 6 4 Connecting the Cables 26 6 5 Connecting Antennas 34 7 Management 35 7 1 SNMP Management Interface 35 7 2 Gateway 5780 Configuration management 35 7 3 Mobile network subscription WWAN backhaul option 37 7 4 Fault management 37 7 5 Performance management 39 7 6 Hardware management 39 7 7 Software managem...

Page 3: ...d No part of this document may be reproduced in any form without the written permission of the copyright owner Disclaimer The contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document ...

Page 4: ...cial in confidence 1 Introduction This document describes how to install the Unlicensed LPWA Gateway 5780 on site The Gateway 5780 can be installed on a wall or on a mast using a Support 6501 with built in AC power supply or a wall plate Figure 1 Gateway 5780 Figure 2 Wall plate Figure 3 Support 6501 ...

Page 5: ...t Port Local O M USB type B 2 WWAN Diversity antenna port Backhaul 3 WWAN Main antenna port Backhaul 4 GNSS antenna port GPS 5 LoRaWAN antenna port 6 SIM card slot WWAN backhaul option 7 RJ45 Socket for Ethernet ETH backhaul and optional PoE input 8 3 wire DC supply DC I to be connected to the optional Support 6501 including PSU 9 LED indicator display 3 LEDs 10 Chassis grounding point ...

Page 6: ...on Make sure that the information in the below documents has been read and understood by the persons performing the procedures Personal Health and Safety Information 1 System Safety Information 2 3 Preparing for Installation 3 1 Required Tools Required tools for installing the gateway are listed in Figure 5 Tools requiredFigure 5 below ...

Page 7: ...er 0 2 6 0 mm Side cutter Ear protection Eye protectors One of the following Wall mounting Hammer drill 230 V AC Cordless hammer drill with 230 V AC charger Hammer drills for voltages other than 230 V AC cannot be ordered from Ericsson Spirit level Allen key 5 mm Torque wrench 0 5 Nm flat screwdriver 2 mm Torque wrench 0 5 4 Nm TORX T10 TORX T20 TORX T30 Torque wrench 5 25 Nm socket 13 mm Figure 5...

Page 8: ... 2 2 Before Starting the Installation Before starting the installation make sure below list is completed The site is prepared per the Site Installation Documentation The ordered hardware is available The power supply for the gateway is installed and tested at the gateway site The site grounding system is installed and tested Either of the following alternatives must be installed and tested A main ...

Page 9: ...hoto of the damages be taken to improve the claim process 2 Remove the straps from the corrugated box 3 Remove the tape from the corrugated box Note Make sure that the items in the corrugated box is not damaged 4 Check that the items delivered correspond to the packing list 5 Carefully place the gateway components on the ground on a clean soft surface or on the packaging material Note Make sure to...

Page 10: ...sson state that installers and users of this Gateway 5780 must only use antennas of a similar type and with the same or lower gain Note that the antenna gain must be configured during installation for correct maximum output power See also chapter 7 2 4 5 1 Accessories for Gateway 5780 Table 1 overview summary of Gateway 5780 and electrical accessory combinations Gateway 5780 KRC161673 10 EU withou...

Page 11: ...s 850 900 1800 1900 Support Frame 6501 KRY 901 345 1 AC to DC unit 115 230V AC to 36VDC AC DC converter and mechanical mounting interface Gateway 5780 EU without WWAN KRC161673 10 LoRa capable Gateway for EU unlicensed band Ethernet LAN backhaul Gateway 5780 unit LoRa 863 870 MHz GNSS receiver 1551 1614MHz Gateway 5780 EU with WWAN KRC161673 11 LoRa capable Gateway for EU unlicensed band Ethernet ...

Page 12: ...Unlicensed LPWA Gateway 5780 1 1553 KRC 161 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 12 45 Commercial in confidence ...

Page 13: ...The recommended melting fuse type is gG gL gD in accordance with IEC 60269 1 Circuit breakers must comply with at least Curve 3 tripping characteristics in accordance with IEC 60934 Minimum fuse rating 6A 2 Power over Ethernet PoE per IEEE 802 3af Note It is required that fusing and over voltage protection is covered via the installation of the Power over Ethernet PoE injector Figure 6 Power alter...

Page 14: ...1 1553 KRC 161 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 14 45 Commercial in confidence 5 1 2 Mechanical Gateway Installation 5 1 2 1 Wall mount installation Figure 7 Wall Mount 5 1 2 2 Pole mount installation Figure 8 Pole Mount ...

Page 15: ...antennas Always follow the guidelines from Ericsson regarding the supported antenna solutions 5 1 3 1 Small Form Factor Antennas e g 2 dBi LoRa antenna Figure 9 Dual 2 dBi antennas LoRa A and WWAN Backhaul 5 1 3 2 Large Form Factor antennas e g 11 dBi LoRa antenna Figure 10 LoRa feeder cable antenna and surge protector according to recommended site material kit NTC 101 02 1 to be connected to B ...

Page 16: ...KRC 161 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 16 45 Commercial in confidence 5 1 4 Power Alternatives 5 1 4 1 Support 6501 Figure 11 115 230 AC power alternative 5 1 4 2 Power over Ethernet Figure 12 Power over Ethernet alternative ...

Page 17: ...iew for wall installation is shown below Figure 13 Drilling Overview for wall installation Steps To install the gateway using a wall installation do the following 1 Mark a hole in the wall for the upper hole position on the gateway and drill a hole The size and type of drill are specified in the site installation plan The maximum screw diameter size is 6 mm Note Wear protective equipment when dril...

Page 18: ...red with the unit They must be specified by the site installation plan 3 Insert a screw in the hole leaving 10 mm of the screw pointing out from the wall Use a flat washer 5 Mark the holes using the two bottom holes in the Support Use a spirit level to make sure the Support is in horizontal level 6 Unhook the Support from the wall 4 Hook the Support onto the screw 7 Drill holes in the wall at the ...

Page 19: ...n on 6 3 6 3Install Support 8 Insert a plug or an expander bolt into the hole Plugs or expander bolts are not delivered with the unit They must be specified by the site installation plan 9 Hook the Support onto the screw 10 Insert screws in the holes 11 Tighten the screws according to the recommendations given by the site installation plan ...

Page 20: ...he wall for the upper hole position on the gateway and drill a hole The size and type of drill are specified in the site installation plan The maximum screw diameter size is 6 mm Note Wear protective equipment when drilling 2 Insert a plug or an expander bolt into the hole Plugs or expander bolts are not delivered with the unit They must be specified by the site installation plan 3 Insert a screw ...

Page 21: ...s in the Wall plate Use a spirit level to make sure the Support is in horizontal level 6 Unhook the Wall plate from the wall 8 Insert a plug or an expander bolt into each hole Plugs or expander bolts are not delivered with the unit They must be specified by the site installation plan 7 Drill holes in the wall at the markings 9 Hook the wall plate onto the screw ...

Page 22: ...idence Continue installation on 6 4 Connecting the Cables 10 Insert screws with flat washers in the holes 11 Tighten the screws per the recommendations given by the site installation plan 12 Hook the gateway onto the wall plate 13 Fold down the gateway 14 Tighten the screws to secure the gateway to the wall plate ...

Page 23: ...ateway using a pole installation do the following 1 Fit the pole clamps to the Support or wall plate 2 Mount the pole clamps around the pole in the desired position 3 Close the latch on the pole clamps 4 Tighten the screws 5 If applicable cut off extra clamp material For wall plate continue from chapter 6 1 2 Using Wall plate For Support 6501 continue from chapter 6 3 Install Support 6501 ...

Page 24: ...source in compliance with the clause 2 5 of the standard IEC 60950 1 Steps To install the Support 6501 do the following 1 Connect the grounding cable This step is not mandatory if the gateway is already grounded See chapter 6 4 2 Loosen the screws on the installation hatch on the support 6501 and remove the installation hatch 3 Loosen the screw in the strain relief 4 Remove the protective plug and...

Page 25: ...673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 25 45 Commercial in confidence 5 Close the installation hatch and tighten the screws 6 Hook the gateway onto the support 7 Fold down the gateway 8 Tighten the screws to secure the gateway to the support ...

Page 26: ... how to connect the power cable antenna cables and PoE cables to the gateway The cable connecting order is as follows 1 Grounding Cable 2 Power Cable 3 Antenna Cables 4 PoE Cables if applicable 6 4 1 Connecting the Grounding Cable Figure 15 Grounding the gateway 1 Connect the grounding cable to the gateway 2 Connect the other end of the grounding cable to mast ground ...

Page 27: ... Ericsson AB 2017 27 45 Commercial in confidence 6 4 2 Connecting the Cables 1 Remove the front cover a Loosen the two screws holding the front cover in place Torque of 200 15 Ncm shall be applied for the screws when lid is replaced b Lift the near end of the front cover ...

Page 28: ... Gateway 5780 1 1553 KRC 161 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 28 45 Commercial in confidence c Remove the cover by pulling it towards you d Lift the cover out of the way and let it hang on the rubber strap ...

Page 29: ... and SIM card must be used See 6 4 4 for SIM card and 6 4 5 Ethernet LAN 6 4 4 3GPP SIM card SIM card to be installed according to picture below Figure 16 Gateway SIM card slot Note Gateway shall be powered OFF when SIM card is inserted Alternatively power cycle gateway after SIM is properly inserted 6 4 5 Ethernet RJ45 for outdoor usage Note ETH needed if ETH backhaul or PoE is to be used Figure ...

Page 30: ...icensed LPWA Gateway 5780 1 1553 KRC 161 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 30 45 Commercial in confidence 6 4 6 Connect the power cable a On the right hand strain relief undo the right hand screw ...

Page 31: ...Unlicensed LPWA Gateway 5780 1 1553 KRC 161 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 31 45 Commercial in confidence b Loosen the left hand screw c Turn the strain relief clockwise ...

Page 32: ...WA Gateway 5780 1 1553 KRC 161 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 32 45 Commercial in confidence d Insert the power cable connector into the PWR port e Press down the cable into the opening A in the gasket ...

Page 33: ... 673 UEN Rev PB9 2017 03 24 Ericsson AB 2017 33 45 Commercial in confidence f Turn the strain relief counter clockwise g Fasten the right hand screw making sure that the strain relief holds the cable in place and then fasten the left hand screw ...

Page 34: ...mmercial in confidence 6 5 Connecting Antennas Antenna connections for the gateway as picture below indicates Figure 18 Antenna connection for jumper cable Connector Description 2 WWAN Diversity antenna port Backhaul 3 WWAN Main antenna port Backhaul 4 GNSS antenna port GPS 5 LoRaWAN antenna port ...

Page 35: ...eway 5780 are sent using SNMP v2 and SNMP v3 traps SNMP can be accessed both locally and remotely SNMP via LMT Local Management Terminal SNMP via ETH backhaul 7 2 Gateway 5780 Configuration management The Gateway 5780 must be configured with a set of configuration parameters in order to function in the correct way 7 2 1 Gateway 5780 General Configuration settings The Gateway 5780 is pre configured...

Page 36: ...he radio parameters under which the Gateway has been certified and approved for correct use The total antenna gain including eventual feeder cable loss in dB for the actual antenna used shall be configured at installation for correct maximum output power capability 7 2 2 Backhaul settings Some general examples of areas that must be configured are listed below For actual installation details refer ...

Page 37: ...Gain dBi Maximum Conducted Output power at Antenna Reference Point dBm Maximum EIRP dBm 2 27 5 29 5 11 25 36 Figure 19 Antenna compensation Note that the antenna gain used must be within the maximum and minimum gain of the antennas listed in Table 1 to be in compliance with regulatory requirements 7 3 Mobile network subscription WWAN backhaul option WCDMA LTE subscription LTE recommended for perfo...

Page 38: ...rrent settings after restart enabled or disabled Figure 20 LED display Red color indicates a major fault It is used to show that there is a fault that must be handled on this unit Green color indicates normal operation I e is used for LEDs that will be lit when the Gateway 5780 is working normally Blue color indicates a warning It is used to show that something a unit or the Node is not working co...

Page 39: ...ate LED indication of the current operational state i e for the steady state the LED can be either ON or OFF reflecting the actual state 4 No network connection no IP Backhaul Slow flashing 0 5 Hz Maintenance LED 1 Power off Steady OFF 2 On or flashing Maintenance needed 7 5 Performance management The purpose of Performance Management is to gather information about Gateway 5780 hardware performanc...

Page 40: ...ll download an upgrade package and perform upgrade On successful upgrade the Gateway 5780 automatically will restart with the new software enabled If the upgrade fails an alarm will be sent and automatically roll back will be triggered 7 8 Security Management The Gateway 5780 is tamper protected for a secure and trustworthy deployment in a network The Gateway 5780 network data service and the oper...

Page 41: ...e 25 MHz to 1 000 MHz Part 1 Technical characteristics and methods of measurement 9 Terminology AC Alternating current ETH Ethernet DC Direct Current GNSS Global Navigation Satellite System GPS Global Positioning System LED Light Emitting Diode LPWA Low Power Wide Area LoRa Long Range Radio see also https www lora alliance org PoE Power over Ethernet PSU Power Supply Unit RJ45 Modular connector us...

Page 42: ...eils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Wireless notice This device complies with FCC ISED radiation exposure limits set forth for an uncontrolle...

Page 43: ...ommunications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase ...

Page 44: ...iance with the essential requirements and other relevant provisions of Directive 1999 5 EC Estonian Käesolevaga kinnitab Ericsson AB seadme Gateway 5780 vastavust direktiivi 1999 5 EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele German Hiermit erklärt Ericsson AB dass sich das Gerät Gateway 5780 in Übereinstimmung mit den grundlegenden Anforderungen und den ü...

Page 45: ...m Ericsson AB oświadcza że Gateway 5780 jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999 5 EC Portuguese Ericsson AB declara que este Gateway 5780 está conforme com os requisitos essenciais e outras disposições da Directiva 1999 5 CE Serbian Ovim putem kompanija Ericsson AB izjavljuje da je ovaj širokopojasni mobilni modul u saglasnosti sa osnovnim zah...

Reviews: