888-24-090-G-00 rev. D • 11/10
1x
1
2
3
4x
9
EN
Auto-Lock Drawer
NOTE: User should
change Master Code
upon receipt of cart.
Erase All Personal Codes (cannot erase only one
code or Master Code):
1 Enter Master Code, then press 1.
2 Press 3 and 5 simultaneously (while blinking).
3 Press 1 and 2 simultaneously.
Lock Drawer (2 methods):
• Wait 4 seconds for drawer to lock automatically
• Press 1 and 2 on number pad simultaneously
Unlock Drawer (3 methods):
• Enter Master Code, then press 1.
• Enter Personal Code, then press 1.
• Key - turn counter clockwise 1/8 turn
Lost Master Code
Contact Ergotron Customer Care for instructions.
AutoLock Drawer Battery Pack
Flashing LED: Meaning
1:
Drawer is open
1 & 2:
Waiting for drawer selection (see
Unlock Drawer
)
3 & 5:
Unit is ready to program master or user codes (see
Programming New Codes
)
5:
Drawer is unlocked
All:
New code accepted
AA
Rechargeable
Nickel Metal
Hydride
Programming New Codes
(Default Master Code: 12345)
1
2
3
4
5
6
7
8
Drawer Troubleshooting
• Key pad numbers are dark
-Touch anywhere on number pad to activate back-light, (drawer remains
locked until you enter valid code)
-Check to make sure DC cable is connected (SV32 models) or battery
pack is connected (SV31 models)
• Code is accepted but drawer does not open
-Make sure drawer is fully closed before entering code.
• Drawer won’t open when Personal Code is entered
-Test system by entering Master Code. If drawer doesn’t unlock, contact
Ergotron customer care for "Lost Master Code" instructions.
Enter Master Code, then press 1.
Numbers 3 and 5 on the Keypad will start fl ashing, indicating the Master Code has been accepted.
Simultaneously press 3 and 5 while they are fl ashing.
All the numbers will light (you have 3 seconds to enter a code).
Enter a new code—any sequence of 5 numbers. (The fi rst code programmed is the new Master Code.)
When the code is accepted, all of the LEDs will fl ash once in acknowledgement (you have 3 seconds to enter the next code).
You can then proceed to program up to 11 personal codes by repeating steps 5 and 6.
When fi nished entering new codes, system will exit program mode after 3 seconds with a series of LED fl ashes.