Super Shot 125 DC 70CFM EU Part Manual
Chapter 8 Troubleshooting
©2022 by Crafco, Inc. All Rights Reserved
………………………………………………………...Troubleshooting (48300N) 8-8
Testing DC Controller
Step
Bench Test DC Controller
1
Remove all wire nuts attaching the DC Controller to the burner.
2
Attach the black ground wire to the negative battery post.
3
Attach the red wire to the positive battery post.
4
Attach the white (Enable) wire to the positive battery post to start the test. (Genesis II
Controllers will have a 15-second delay.)
•
Orange (Blower Motor) wire should have 12Vdc (all the time).
•
Blue (Igniter) wire should have 12Vdc.
• Purple (Fuel Solenoid) wire should have 12Vdc (after the delay).
5
Twist the yellow wires together (once voltage registers) on the orange, blue and purple wires.
•
Orange (Blower Motor) wire should maintain 12Vdc.
•
Blue (Igniter) wire should lose voltage after 15 seconds.
•
Purple (Valve) wire should maintain 12Vdc.
• Purple (Fuel Solenoid) wire should maintain 12Vdc.
6
If any of the above tests fail, replace the DC Controller.
Burner Fuel Solenoid Testing
Step
Fuel Solenoid Test
1
Remove cord set from fuel solenoid.
2
Check the ohms between the terminals of fuel solenoid.
3
If the reading is between 15-25 ohms the coil is good.
4
If the reading is outside the above range or the meter indicates an open circuit, replace the
fuel solenoid.
Table 8-8 Testing the DC Controller
Table 8-9 Burner Fuel Solenoid Test
Summary of Contents for Crafco SUPER SHOT 125
Page 1: ...Parts Manual 26635N Revision E SUPER SHOT 125 DIESEL COMPRESSOR 70CFM EU MELTER...
Page 4: ...Super Shot 125 Diesel Compressor 70 CFM EU Melter PN 48300N...
Page 5: ......
Page 16: ......
Page 26: ......
Page 42: ......
Page 72: ......
Page 76: ......
Page 120: ......
Page 170: ......
Page 174: ......
Page 175: ......
Page 176: ...2022 Crafco Inc...