Technical data
10/2018
1020141-00
Operating instructions – 73/80
5.3
Lamp sets
WARNING!
The conformity declaration applies for the specified UV
lamps and filer panels. The use of other UV lamps and filter
panels voids the operating licence.
Moreover, the UV lamps must be marked with a matching
equivalence key, see attachment page 75.
The UV lamps used are broadband radiators that can be operated with differ-
ent wattages (approx. 240-520 W).
5.3.1
PRESTIGE 1150
INTELLIGENT PERFORMANCE /
PRESTIGE 1150 INTELLIGENT PERFOR-
MANCE AF & AROMA
Lamp set (UV-typ 2)
Number Description
Length
Power
Control
Order-no.
a)
4
4
UV high pressure lamps Ergoline ULTRA
Filter panels Ultra Performance 842 H TREND
420 W
420 W / 360 W /
260 W / 0 W
12645-..
1005802-..
b)
2
2
2
UV high pressure lamps Ergoline ULTRA
Filter panels Ultra Performance 912 (blue)
Filter panels uncoated
250 W
240 W / 0 W
1500384-..
1500635-..
1500160-..
c)
20
UV low pressure lamps
Ergoline TREND DYNAMIC160 W E40
1,80 m
80-160 W 80-160 W
1508551-..
d)
8
UV low pressure lamps
Ergoline TREND DYNAMIC160 W E40
1,80 m
80-160 W 80-160 W
1508551-..
e)
24
UV low pressure lamps
Ergoline TREND DYNAMIC160 W E40
1,80 m
80-160 W 80-160 W
1508551-..
f)
3
3
UV low pressure lamps
Ergoline TREND 8 W E29
Starter S10 (4-65 W)
0,31 m
8 W
8 W / 0 W
1508223-..
10047-..