Cleaning and maintenance
56/80
4.8.4
High pressure lamps and filter panels
UV high pressure lamps are used in the facial tanner and the shoulder tanner.
DANGER!
Danger of burns from hot lamps and surfaces!
Finger and hands may get burned when replacing lamps
and filter panels or cleaning reflectors.
–
Before carrying out maintenance work, wait until the
device has cooled down sufficiently.
Fire hazard due to overheated lamps!
Non-approved high pressure lamps can explode. Hot lamp
components can set other parts on fire. People can be killed
or severely injured due to smoke inhalation and fire.
–
Only fit the high pressure lamps specified by the manu-
facturer.
–
Clean the inside of the device regularly. Dust particles
are flammable!
WARNING!
Danger of overheating will exist if the wrong
UV high pressure lamps are used!
The danger of overheating will exist if the wrong UV high
pressure lamps are fitted in the shoulder tanner. The device
might be damaged.
–
Never interchange the UV high pressure lamps used in
the facial tanner with those used in the shoulder tanner!
–
Open the clamps.
–
Lift the filter panel, pull it out of the guide and remove it.
–
Unplug the UV lamps.
–
Clean the reflector.