Cleaning and maintenance
10/2018
1020141-00
Operating instructions – 61/80
4.12
Cleaning or replacing the UV lamps
and filter panels in the shoulder tan-
ner
DANGER!
Danger of burns from hot lamps and surfaces!
Finger and hands may get burned when replacing lamps
and filter panels or cleaning reflectors.
–
Before carrying out maintenance work, wait until the
device has cooled down sufficiently.
–
Remove one screw from each one.
–
Remove both housings and carefully lay them aside.
Changing the UV high pressure lamps: see page 56.
WARNING!
Danger of overheating will exist if the wrong
UV high pressure lamps are used!
The danger of overheating will exist if the wrong UV high
pressure lamps are fitted in the shoulder tanner. The device
might be damaged.
–
Only Ergoline ULTRA UV high pressure lamps
(1500384-..) are to be fitted in the shoulder tanner.
Each of the high pressure lamps in the shoulder tanner is fitted with 2 different
filter panels. The two filter panels are secured in place inside the housing.
–
Remove the screws.