![Ergofix ELECTRIC HEIGHT ADJUSTABLE TABLE Assembly And Operation Instructions Manual Download Page 12](http://html.mh-extra.com/html/ergofix/electric-height-adjustable-table/electric-height-adjustable-table_assembly-and-operation-instructions-manual_2422132012.webp)
Error Code Key
Code Meaning
Suggested Actions
E01
Power supply exceed input voltage
range.
Check if power supply is within required input
voltage range.
E02
Lift columns unbalanced by > 10mm.
Perform reset procedure.
E03
Handset not connected.
Plug handset wire connector into the control
box.
E04
Handset communication error.
Check handset for damage. Reconnect handset
wire connector into the control box.
E05
Obstacle detected, anti-collision
activated.
Release depressed button.
E06
Start up error.
Reconnect all cable connectors into control box.
If problem persists, check with technical
support.
E07
Control system error.
Perform reset procedure.
E08
Table tilts during height adjustment.
Perform reset procedure.
E09
Overheated or duty cycle limit was
reached.
Let the table electronics cool down for at least
18 minutes before using.
E11/21
Motor M1/M2 is not connected.
Plug M1/M2 motor cable connectors into the
control box.
E12/22
Motor M1/M2 current sampling error.
Reconnect M1/M2 motor cable connectors into
control box. If problem persists, check with
technical support.
E13/23
Phase loss or phase line disconnected
from motor M1/M2.
Reconnect M1/M2 motor cable connectors into
control box. If problem persists, check with
technical support.
E14/24
Hall sensor error or hall sensor wire
disconnected from motor M1/M2.
Reconnect M1/M2 motor cable connectors into
control box. If problem persists, check with
technical support.
E15/25
Motor M1/M2 internal circuit error.
Reconnect M1/M2 motor cable connectors into
control box. If problem persists, check with
technical support.
E16/26
Motor M1/M2 stalled.
Perform reset procedure.
E17/27
Motor M1/M2 directional error.
Reconnect M1/M2 motor cable connectors into
control box. If problem persists, check with
technical support.
E18/28
Table overloaded.
Reduce weight on the table.
OPERATION GUIDE