background image

4

Operators Manual ES-648E 

AKKUVEC

Explanation of Symbols

In this operating manual and on the device itself there 

are warnings, which are identified by symbols or terms. 

Here is a list of these symbols and terms, as well as their 

meaning for the user.

IMPORTANT:  

 

Information on proper use and protection of the leaf 

and waste suction unit against damage.

Read and observe the operating instruc-

tions.

Protecting Limbs

Highest risk of injury!

Wear suitable protective equipment

Protecting eyes and ears.

Hot Surfaces

Risk of burns!

Electrical voltage 48V

DANGER

This symbol, in connection with the term 

DANGER, indicates facts or circumstances 

which may lead to serious injury or death of 

the operator or bystanders.

WARNING

This symbol, in connection with the term 

WARNING, indicates possible sources of 

danger which may lead to serious injury or 

death of the operator or bystanders.

CAUTION

This symbol, in conjunction with the word 

CAUTION, indicates possible hazards that 

may result in injury to the operator or by-

stander.

General

•  Follow the instructions in this manual for safe handling 

of the leaf and waste suction unit.

•  A prerequisite for safe use of the device is compliance 

with all safety instructions.

•  The operator must have read and understood these 

operating instructions carefully before starting any 

work.

•  Before driving and transporting on public roads, the 

applicable traffic regulations must be observed.

•  The general safety regulations and local accident 

prevention regulations must also be observed.

•  The work safety regulations must be observed. 

The operator must have access to the operating in-

structions at all times. 

Protective Equipment

During operation of the leaf and waste suction unit, the 

operator must ensure that
•  sturdy footwear,
• 

tight-fitting clothing,

•  safety gloves,
•  hearing protection and
•  goggles
to carry it.
Please also observe the information under Safety in-

structions.

Safety Devices

Safety devices must not be removed or taken out of 

service during operation of the leaf and waste suction 

unit. The unit never be operated without a suction trunk 

or collection bag.
Immediately repair any damage to the safety devices, 

suction trunk or collection bag.

Behaviour in Case of Danger

•  Stop walking right away,
•  Stop the engine,
•  Exit the device,
•  Correct dangerous situation.

Summary of Contents for AKKUVAC ES-648E

Page 1: ...555 Metzingen Telefon 07123 96830 Telefax 07123 9683258 http www echo motorgeraete de email info echo motorgeraete de WARNING Read the instructions and safety regulations carefully before starting to...

Page 2: ...Lever 10 Adjusting Spindle for Suction Trunk 10 Operating Instructions Start the machine 11 Shutting down the machine 11 In an emergency situation 11 Installing the collecting bag 11 Empty the collec...

Page 3: ...ner will make your work much easier and more enjoyable A suction hose is also available for this unit which makes it easier to work under bushes on stairs or in other places that are difficult to acce...

Page 4: ...ctions in this manual for safe handling of the leaf and waste suction unit A prerequisite for safe use of the device is compliance with all safety instructions The operator must have read and understo...

Page 5: ...coal danger to life due to burns Danger from Engine Operation Batteries Do not place any objects on the batteries do not cover ventilation slots Only use the original charger to charge the batteries...

Page 6: ...ifficult dusty and wet operating conditions the bag should be cleaned at shorter intervals see operating instructions 8 If damp foliage and soil is sucked in with the leaf vacuum cleaner the turbine h...

Page 7: ...Collection Bag 3 Control Unit 4 Hight adjustment suction Trunk 5 Ejection Channel 6 Turbine Housing 7 Suction Trunk 8 Wheel 9 Electrical Motor and Batteries 10 Clutch Lever 11 Charger socket 12 Brake...

Page 8: ...ade with them either The control lamp j lights up yellow during trouble free operation If a fault occurs it lights RED A red light up during starting does not represent a fault but is part of the self...

Page 9: ...ERCO Z 7501 E48 20 charger To do this place the unit in a dry level place and secure it by applying the handbrake Connect the charger and the ES 424E to the battery charging cable The charger switche...

Page 10: ...cannot roll away Before you continue working release the handbrake Adjusting spindle for suction trunk Adjusting Spindle for Suction Trunk The adjustment spindle for the infinitely variable height adj...

Page 11: ...de and attached to the 4 brass coloured bolts Empty the collection bag Stop the engine before opening the collecting bag Open the zipper or toggle fastener on the collecting bag and remove sucked in m...

Page 12: ...t on the right side of the machine The end of the charging time is indicated by a green LED The charging time depends on the state of dis charge of the battery With a 20 ampere charging current the fo...

Page 13: ...does not improve the suction performance If the setting is too high there is a lack of suction power and the suction power is unsatisfactory Dry leaf suction Dry leaf is crushed by the turbine during...

Page 14: ...turbine casing accordingly Slide the suction hose onto the mounting flange and tighten the hose clamp Always switch off the engine to change between the suction hose and the suction trunk DANGER Never...

Page 15: ...e lance of a high pressure cleaner or with a hose If you allow the engine to run for a short time after splashing the bag it will dry quickly You can also clean the collection bag in a water bath or h...

Page 16: ...r ceramic fragments and metal parts There may be sharp edges in the unit Always wear protective gloves when working on the turbine and removing blockages Risk of injury due to sharp edges DANGER Befor...

Page 17: ...th disc brake Tyres air protected against thorns 4 00 4 Tire pressure 1 5 bar Height adjustment suction trunk 0 10 cm stepless Working width of suction trunk 750 mm Max Air volume 46 00 m Min Measured...

Page 18: ...ed according to EN ISO14982 2009 EN 60335 2 69 2009 IEC 60335 1 2010 and compliance with these guidelines has been checked by T V Rheinland Place of storage of the technical documentation ECHO Motorge...

Page 19: ...19 Operators Manual ES 648E AKKUVEC...

Page 20: ...tr 7 D 72555 Metzingen Tel 0049 7123 96830 Fax 0049 7123 9683258 info echo motorgeraete de www echo motorgeraete de All figures are approximate We reserve the right to change specification without pri...