<state>
0
UART1 RS232 interface is enabled (default)
1
UART1 RS232 interface is disabled (the RxD remains active allowing the unit to
continue to receive commands)
<mode>
0 Normal
(default)
1
UART 2 RxD and TxD redirected to UART1 DSR and DTR (does not require reset and
external mode)
Examples :
Command
Possible Responses
Notes
AT+WIOW
AT+WIOW=(0,1,7,8),(0-1)
OK
Display syntax
AT+WIOW=0,1
OK
Open-collector output is
set high
AT+WIOW=1,0
OK
UART1 RS232 interface is
enabled
AT+WIOW=7,1
OK
UART2 RxD/TxD
redirected to UART1
DSR/DTR
2.1.9
AT+WGPSANT – GPS antenna configuration
This command manages the GPS antenna configuration.
Syntax: AT+WGPSANT=<type>[,<mode>][,<mon>]
Response syntax: +WGPSANT: <type>,<mode>
: <type>,<mon>
: <type>,<status>,<presence>,<voltage>
Unsolicited response syntax: +WGPSANT: <type>,<status>,<presence>,<voltage>
<type>
0
Antenna configuration (see
<mode>
below)
1
Antenna monitoring management (see
<mon>
below)
2
Antenna status (see
<status>
below)
<mode>
0
0v (antenna not powered)
1
3v internal (default) (antenna powered)
<mon>
0
Monitoring is deactivated (default)
1 Monitoring
is
activated
<status>
0
Antenna is not powered
1
Antenna is powered
Note : In the case of a short circuit, the hardware protection disconnects the antenna,
causing an open circuit. After a 10-second delay the antenna is re-powered.
<presence>
0 No
antenna
connected
1 Antenna
connected