Chapter 5: CCM Appliance Commands
47
Example
The following command sets a baud rate of 57600 and enables XON/XOFF flow control on port 2.
> port 2 set baud=57600 flow=xonxof
SOCKET=<
socket
>
TCP port that must be entered on the Telnet client to connect to this serial port. The
new value becomes effective in subsequent sessions.
When SSH is enabled, the CCM appliance automatically adds 100 to the
specified value.
When All is specified, port 1 will be assigned the specified socket value plus 1, port 2
will be assigned the specified value plus 2, and so on. When All is specified and SSH
is enabled, port 1 will be assigned the specified socket value plus 101, port 2 will be
assigned the specified value plus 102, and so on.
When both plain text Telnet and SSH connections are enabled, the +100 value will
not appear in displays.
Default = 3000 plus the port number, 3100 plus the port number if SSH is enabled;
see above for action taken if All is specified
CHAR=^<
cli_char
>
CLI access character in the range A to _ (underscore) or None. (The allowable ASCII
range is 0x41-0x5F and 0x61-0x7A.) The CLI access character, when pressed
simultaneously with the
Ctrl
key during a session with an attached serial device, will
suspend the session with the device and place you in CLI command mode. If None is
specified, the value specified in the Char parameter of the Server CLI command will
be used.
Default = None
TOGGLE=NONE|DTR
When set to DTR, the CCM appliance will toggle the port’s DTR-out signal off for 1/2
second each time a connection is made to the port. This toggle is required to awaken
the console port of some devices.
Default = None
POWER=<
signal
>
Control signal to monitor and the state that indicates the target device has power on.
The entire value must be specified; abbreviations are not allowed. The power status
monitoring signal cannot also be used for flow control. Valid values are:
None
Disables power status monitoring.
HICTS
CTS high indicates power on.
LOCTS
CTS low indicates power on.
HIDCD
DCD high indicates power on.
LODCD DCD low indicates power on.
HIDSR
DSR high indicates power on.
LODSR DSR low indicates power on.
Default = None
Table 5.8: Port Set Command Parameters (Continued)
Parameter
Description
Summary of Contents for Equinox Console Manager CCM4850 CCM4850 CCM4850
Page 8: ...vi CCM4850 Installer User Guide...
Page 10: ...viii CCM4850 Installer User Guide...
Page 16: ...4 CCM4850 Installer User Guide...
Page 44: ...32 CCM4850 Installer User Guide...
Page 82: ...70 CCM4850 Installer User Guide...