Notice:

Be sure to follow the diagrams below when making your own cables.  
Do not connect the cables shield conductor to the ground lug or  
allow the shield conductor to come in contact with the XLRs  
outer casing. Grounding the shield could cause a short circuit  
and erratic behaviour.

 

Line termination:

When longer runs of cable are used,  
you may need to use a terminator on  
the last unit to avoid erratic behaviour.

Using a cable terminator will decrease  
the possibilities of erratic behaviour. 
(3-pin - Order ref: CABL90,  
5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

5-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

DMX setup

Termination reduces signal 

transmission problems and 

interference. It is always 

advisable to connect a DMX 

terminal, (resistance 120 

Ohm 1/4W) between pin 2 

(DMX-) and pin 3 (DMX+) of 

the last fixture.

5-Pin

1

2

4

5

3

3-Pin

1

2

3

Pin Configuration

3-Pin

5-Pin

Pin 1 - Ground

Pin 2 - Negative

Pin 3 - Positive

Pin 4 - N/C

Pin 5 - N/C

1

2

3

1

2

3

DMX 512

3-Pin XLR output

DMX 512

3-Pin XLR input

GROUND

DMX +

DMX –

DMX 512

5-Pin XLR output

DMX 512

5-Pin XLR input

1

2
4 5

3

1 2

4

5

3

GROUND

N/C

DMX –

N/C

DMX +

1 ground

3 hot

2 cold

3-Pin XLR male

3-Pin XLR female

2 cold

3 hot

1 ground

2 cold

1 ground

5 N/C

3 hot

4 N/C

5-Pin XLR male

5-Pin XLR female

4 N/C

5 N/C

1 ground

3 hot

2 cold

Summary of Contents for EQLED203

Page 1: ...Order code EQLED203 Super Boogie User Manual...

Page 2: ...s life Only use the equipment indoors Do not sit the equipment on a flat surface as this can block the air intake to cool the LED Do not expose to flammable sources liquids or gases Always disconnect...

Page 3: ...and built in show modes 24 x 3W LEDs R 6 G 6 B 6 A 6 Beam angle 78 DMX channels 4 6 or 26 selectable Auto sound active and master slave modes 0 100 dimming and variable strobe IR remote control includ...

Page 4: ...UT DMX OUTPUT SAFETY ETE www prolight co uk MENU ENTER MIC DOWN UP POWER OUTPUT 100 240V 50 60Hz POWER INPUT 100 240V 50 60Hz FUSE F3A 250V POWER CONSUMPTION 72W SAFETY ETE www prolight co uk MENU ENT...

Page 5: ...d r DMX address setting N A S t S L 1 S L 2 S L n d Master slave mode t e s t Auto Test 5 o 0 5 o 1 6 5 e 9 9 5 e 0 S o U n Sound active v e r Firmware Version v 1 0 o N o F F L E d Display blackout D...

Page 6: ...f the unit to show Chnd on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 4 or 26 DMX channel modes Press the ENTER button to confirm the setting To ex...

Page 7: ...00 000 255 13 Blue 3 dimmer 0 100 000 255 14 White 3 dimmer 0 100 000 255 15 Red 4 dimmer 0 100 000 255 16 Green 4 dimmer 0 100 000 255 17 Blue 4 dimmer 0 100 000 255 18 White 4 dimmer 0 100 000 255 1...

Page 8: ...the LED display Now press the ENTER button and use the UP and DOWN buttons to choose between So 0 to So16 Press the ENTER button and use the UP and DOWN buttons to select the sound sensitivity between...

Page 9: ...ENTER button The unit will now display the fixtures software version e g u10 To exit out of any of the above options press the MENU button IR remote functions Button functions 01 Sets the unit into bl...

Page 10: ...ll makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmis...

Page 11: ...e adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Si...

Page 12: ...UP POWER OUTPUT 100 240V 50 60Hz POWER INPUT 100 240V 50 60Hz FUSE F3A 250V POWER CONSUMPTION 72W DMX INPUT DMX OUTPUT SAFETY ETE www prolight co uk MENU ENTER MIC DOWN UP POWER OUTPUT 100 240V 50 60...

Reviews: