30
17. Troubleshooting and maintenance
Error code on
the display
Problem
Solution
Battery symbol
(
)
Battery voltage
too low
Replace batteries
F1
Valve drive sluggish Check the installation;
check whether the pin on
the heating valve is stuck
F2
Actuating range
too wide
Check the fastening of
the actuator
F3
Actuating range too
narrow
Check the heating valve;
check whether the valve
pin is jammed
F4
A MAX! Cube
has already been
taught-in
Reset the device and
repeat the teach-in
procedure
Symbol for radio
synchronicity
flashing slowly (
)
Connection to
taught-in MAX!
Components lost
Check the power supply
to taught-in MAX!
Components
Symbol for radio
synchronicity
flashing fastly ( )
Duty cycle has
been exceeded
The longest period to
wait before sending
again would be an hour
LOC
Operating block
activated
Follow the instructions
in the section 13 to
deactivate the operating
block
CAL
Routine descaling
is active
Automatic function, see
the section 16