27
11. Open window function
The actuator reduces the temperature in the room
automatically during ventilation, in order to save on heat-
ing costs. During ventilation, the window open symbol (
)
is displayed.
Without MAX! Window Sensor:
A MAX! Radiator Thermostat is able to automatically
detect a sharp fall in temperature caused by ventilation
(temperature fall detection). The temperature is then
reduced to 12°C for 15 minutes (default factory setting).
With MAX! Window Sensor:
When a MAX! Window Sensor is used, the opening and
closing of a window is detected at the precise time it
occurs. Whilst the window is open, the temperature is
reduced to the factory setting of 12°C. When the MAX!
Window Sensor detects the closing of the window, all
MAX! Radiator Thermostats installed in the room are
immediately reset to their original mode.
The open-window temperature and time can
be set via the MAX! Software. Temperature fall
detection without a MAX! Window Sensor can also be
deactivated (by setting the duration to 0 minutes)
via the software.
When a MAX! Window Sensor is taught in, the MAX!
Radiator Thermostat does not react to a tempera-
ture fall.