Rev. A
Installation 2-7
UB-E02 Technical Reference Guide
2.6 Initializing UB-E02
All the parameters of internal settings for the UB-E02 can be set to the factory default values.
Follow the steps below:
1. Turn off the printer power. Be sure to confirm that the LED lights are off.
2. Turn on the printer power while pressing the switch of the UB-E02 and hold the switch until
the factory default values are printed.
3. After "Resetting to Factory Default!" is printed, release the switch.
4. Initialization takes approximately 30 seconds. Do not turn off the printer power during the
initialization.
5. When the initialization is finished, the status sheet is printed. The following are printed on
the status sheet.
•
TCP/IP settings
•
SNMP settings
•
MAC address and version of UB-E02
•
Other status items of UB-E02
CAUTION:
Do not turn off the printer power until the status sheet is printed out.
2.7 UB-E02 Status Sheet Printing
The internal setting parameters of the UB-E02 can be printed. Follow the steps below:
1. Confirm that the printer power is on and the printer is ready for printing.
2. Press the switch of the UB-E02 and hold the switch more than 3 seconds.
3. After the status sheet printing starts, release the switch.
Summary of Contents for UB-E02