EPSON Stylus PHOTO 895/785EPX/915/825
Revision B
Disassembly and Assembly
Disassembly
94
4.2.10 HP/PE Sensor removal
1.
Remove the Housing from the printer. (Refer to Section 4.2.1 "Housing
Removal")
2.
Remove the LD roller from the LD roller shaft holder. (Refer to Section 4.2.9 "LD
Roller removal")
3.
Remove HP or PE detection lever from the LD roller shaft holder and disconnect
the cable from the sensor connector
Figure 4-36. Removing the HP or PE detection lever
4.
Release each two hooks of HP and PE sensors securing them from the LD roller,
then remove the sensors.
HP detection lever
PE sensor
HP sensor
Fixing nooks
Fixing nooks
PE detection lever
C H E C K
P O I N T
Tor
Make sure that the Torsion spring 0.22 is hung to the following
suitable position
Figure 4-37. Torsion spring 0.22 for PE detection lever
Figure 4-38. Torsion spring 0.22 for HP detection lever
PE detection lever
Torsion spring 0.22
HP detection lever
Torsion spring 0.22
Summary of Contents for Stylus Photo785EPX
Page 1: ...EPSON STYLUSPHOTO895 785EPX 915 825 Color Inkjet Printer SEIJ01001 SERVICE MANUAL ...
Page 9: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 31: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 55: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 69: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 116: ...C H A P T E R 5 ADJUSTMENT ...
Page 137: ...C H A P T E R 6 MAINTENANCE ...
Page 146: ...C H A P T E R 7 APPENDIX ...
Page 175: ...EPSON STYLUS PHOTO 825 915 331 451 450 A C498 ELEC 001 Rev 01 No 03 200 300 330 A ...
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ......