Disassembly and Assembly
4.2.2 Scanner Unit
1.
2.
Remove the FFC Cover.
3.
Disconnect the FFCs (x2) of the Scanner Unit from the Main Board, together with the
FFC Clamp.
4.
Remove the screws (x2).
5.
Lift the Scanner Unit carefully, and unplug the ground cable from the printer frame.
(Continued to next page)
Figure 4-5. Removing the Scanner Unit
C A U T I O N
When removing the Scanner Unit, take care not to break the
ground cable, which is connected to the printer.
With the FFC disconnected, take care not to break the ferrite
cores by hitting them against each other.
C H E C K
P O I N T
Remove the Scanner Unit, while holding it in an open position,
from the printer body.
Torque: 0.6 ± 0.1N
⋅
m
C.B.P-Tite 3x10 F/NI (x2)
FFC Cover
Disconnect ground cable from frame
FFC Clamp
Scanner Unit
Chassis Assy (LCD Assy)
Summary of Contents for Stylus Photo RX700 Series
Page 1: ...EPSON StylusPhotoRX700 Scanner Printer Copier SERVICE MANUAL ECOS SEMF05001 ...
Page 9: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 17: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 51: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 76: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 133: ...C H A P T E R 5 ADJUSTMENT ...
Page 146: ...C H A P T E R 6 MAINTENANCE ...
Page 163: ...C H A P T E R 7 APPENDIX ...
Page 175: ...Model PM A900 Stylus PHOTO RX700 Board C583Main Sheet 1 3 Rev H ...
Page 176: ...Model PM A900 Stylus PHOTO RX700 Board C583Main Sheet 2 3 Rev H ...
Page 177: ...Model PM A900 Stylus PHOTO RX700 Board C583Main Sheet 3 3 Rev H ...
Page 178: ...Model PM A900 Stylus PHOTO RX700 Board C583 PNL PNL B Sheet 1 1 Rev C ...
Page 179: ...Model PM A900 Stylus PHOTO RX700 Board C583PSB Sheet 1 1 Rev H ...
Page 180: ...Model PM A900 Stylus PHOTO RX700 Board C583PSE Sheet 1 1 Rev F ...