Adjustment Using Adjustment Program
228
Confidential
5. Place the thickness gauge 0.9mm on the location described in
.
Figure 5-20. Placement of the Thickness Gauge
6. Close the scanner and confirm the Cover open sensor condition changes to
“Closed!”.
Figure 5-21. Case open sensor check (4)
7. Open the scanner and replace the gauge to the thickness gauge 3 mm, and confirm
the Cover open sensor condition changes to “Open!” even when the scanner is
closed. (Refer to Figure 5-19.)
8. Press “CD/DVD tray” button to return to “Special Inspection” menu.
9. By pressing the “Power” button, turn off the printer to complete Check 1, and
continuously.
Front left
Place the gauge (0.9mm)
aligning it with the edge
of Upper Housing.
Sensor Check
Cover open sensor condition
Close!
Photo Tray sensor condition
Open!
DUP unit sensor condition
Open!
After Check
Push [CDR Guide] Button
C H E C K
P O I N T
If you confirm that the cover open sensor is not operating correctly
in
, check the connection of FFC between the
cover open sensor and the Main Board. If the correct connection
cannot improve the symptom, replace the scanner unit with a new
one.
Summary of Contents for Stylus Photo Printer PX800FW
Page 11: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION http www manuals4you com ...
Page 46: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES http www manuals4you com ...
Page 52: ...Confidential C H A P T E R 3 TROUBLESHOOTING http www manuals4you com ...
Page 92: ...Confidential C H A P T E R 4 DISASSEMBLY ASSEMBLY http www manuals4you com ...
Page 208: ...Confidential C H A P T E R 5 ADJUSTMENT http www manuals4you com ...
Page 246: ...Confidential C H A P T E R 6 MAINTENANCE http www manuals4you com ...