Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Revision C
DISASSEMBLY/ASSEMBLY
Disassembly/reassembly procedures specific to Artisan 700/PX700W/TX700W
186
Confidential
7.
Lift the Hinge on the right side in the direction of the arrow (1), and slide the
Scanner Unit in the direction of the arrow (2), and remove it.
Figure 4-206. Removing the Scanner Unit (3)
Scanner Unit
1
2
When installing the Scanner Unit, follow the procedure below.
1. Align and insert the dowel of the Scanner Unit to the
positioning hole of the printer (Left inside).
2. Align and insert the rib of the Scanner Unit to the groove of
the Hinge.
Figure 4-207. Installing the Scanner Unit (1)
3. While aligning and inserting the rib of the Scanner Unit to
the groove of the Hinge, secure them with the screw (x1)
temporarily with the screw holes aligned as shown in
. It is recommended to prepare a pillow-shaped
supporter to keep this position. (See
.)
(Continued to the next page.)
Hole
Dowel
Left
inside
Rib of the Scanner Unit
& groove of the Hinge
Right
inside
Summary of Contents for Stylus Photo Printer PX800FW
Page 11: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION http www manuals4you com ...
Page 46: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES http www manuals4you com ...
Page 52: ...Confidential C H A P T E R 3 TROUBLESHOOTING http www manuals4you com ...
Page 92: ...Confidential C H A P T E R 4 DISASSEMBLY ASSEMBLY http www manuals4you com ...
Page 208: ...Confidential C H A P T E R 5 ADJUSTMENT http www manuals4you com ...
Page 246: ...Confidential C H A P T E R 6 MAINTENANCE http www manuals4you com ...