Rev.A
BIOS Setup 3-15
Developer's Guide SR-600
Confidential
Device Diagnostics Utility
Operational check for the devices connected to the SR-600 is accomplished.
The device diagnostics utility can perform the following tests:
•
TM printer printing test
•
Customer display test
•
Cash drawer operation test
•
Serial port loop-back test
•
LPT1 port loop-back test
•
Printer connected to LPT1 printing test
•
Ethernet loop-back test
Conditions for Running Device Diagnostics
Device diagnostics utility is performed under the following conditions shown in the table.
Table 3-9 Conditions
Setting
Condition
Connection to the TM printer
The TM printer needs to be connected to
SR-600. Connect the
printer to either COM port or LPT1, even if you will not test the TM printer.
Setting of the TM printer DIP
switches
Set the receiving buffer to maximum. Set selection switch (customer display
connection / non-connection) to non-connection (if it has a selection
switch). Set the communication settings following the instructions, if the TM
printer does not have an ID function. (ESC/POS
GS I
command).
Baud Rate : 9600 bps
Word Length : 8 bits
Parity : None
Refer to the TM printer manual for the setting procedure.
DM display connect port
Connect the DM display to DM display port, when the DM display is tested.
Setting of DIP switches for the DM
display
When the TM printer is connected to COM1:
Set the communication settings following the instructions, when the TM
printer has the ID function (ESC/POS
GS I
command).
Baud Rate: Same setting as for the TM printer (9600 bps)
Word Length: Same setting as for the TM printer (8 bits)
Parity: Same setting as for the TM printer (None)
Set the communication settings following the instructions, if the TM printer
does not have the ID function. (ESC/POS
GS I
command).
Baud Rate : 9600 bps
Word Length : 8 bits
Parity : None
When the TM printer is connected to another port besides COM1:
Set the DM display communication settings following the instructions.
Baud Rate : 9600 bps
Word Length : 8 bits
Parity : None
Refer to the DM display manual for the setting procedures.
Summary of Contents for SR-600
Page 1: ...Confidential Developer s Guide SR 600 Issued date Issued by EPSON English 401333300 ...
Page 2: ...Confidential ...
Page 21: ...Rev A General Features 1 11 Developer s Guide SR 600 Confidential Required Clearance 5cm 5cm ...
Page 22: ...1 12 General Features Rev A Confidential ...
Page 44: ...2 22 OS and Driver Setup Rev A Confidential ...
Page 106: ...5 24 Hardware Specifications Rev A Confidential ...
Page 154: ...6 48 Peripherals Option Installation Rev A Confidential ...
Page 186: ...Appendix 3 8 Wake On LAN Rev A Confidential ...
Page 191: ...Confidential ...
Page 192: ...Confidential EPSON SEIKO EPSON CORPORATION Printed in Japan ...