Format
ICE CONTROL SOFTWARE ICS62XX
S1C62 FAMILY
EPSON
VIII-27
DEVELOPMENT TOOL REFERENCE MANUAL
HISTORY DATA DISPLAY
H
#H,
<pointer 1>
,
<pointer 2>
#H,
<pointer 1>
Displays history data.
(1) Displays history data from <pointer 1> to <pointer 2>.
(2) When <pointer 2> defaults, displays history data of <pointer 1> in 21 lines.
(3) Numerals displayed in <pointer 1> and <pointer 2> are decimal, from 0 to 9999.
(4) The following contents are displayed for each instruction:
LOC:
History pointer (decimal)
PC:
Program counter (hexadecimal)
When a break, "PC" is displayed.
IR:
Command code (hexadecimal)
OP:
Command mnemonic
OPR:
Command operand
A,B,X,Y:
Contents of A, B (Xp, Xh, Xl), (Yp, Yh, Yl) registers
IDZC:
Binary display of flag bit (1 when set, 0 when clear)
Other:
During execution of an instruction, the memory R/W cycle and data are
displayed. Also, data interrupts INT1 (stack data) and INT2 are displayed
(5) History memory has a capacity of 8192 bus cycles. One the other hand, the S1C62 Family
has 5, 7 and 12 clock instructions. The 5 clock instructions require three bus cycles, 7 clock
instructions require four bus cycles, and 12 clock instructions require six bus cycles. Thus,
the final value of the history pointer is changed according to the executed instruction. The
maximum final value of the execution time for only a 5 clock instruction is approximately
2700, while the execution time for a 12 clock instruction is about 1300. When a break
occurs before the history memory reaches the end, the last value of the history pointer is
reduced.
(6) The history memory receives new data until a break occurs. Old data is erased when
number of executed GO commands exceeds 2700.
(7) The top of the history pointer is 0. When the last value of <pointer 2> is set, the values are
displayed to the last value.
(8) When there are no history data (Before GO command, after GO command execution,
during T command execution, or during HAR command execution), the following
message is displayed:
* NO HISTORY DATA *
(9) The HB command can be used to view history data immediately prior to a break.
Function
Summary of Contents for S1C62 Family
Page 1: ...MF599 06 Development Tool Reference Manual CMOS 4 BIT SINGLE CHIP MICROCOMPUTER S1C62 Family ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 20: ......
Page 22: ......
Page 26: ......
Page 28: ......
Page 30: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 70: ......
Page 72: ......
Page 74: ......
Page 82: ......
Page 84: ......
Page 86: ......
Page 98: ......
Page 100: ......
Page 112: ......
Page 206: ......
Page 208: ......
Page 210: ......