Perfection 4870 Photo
Revision A
PRODUCT DESCRIPTION
Error-time Processing
17
1.6 Error-time Processing
Table 1-3. Error Definition and Remedy List
Category
LED Indication
Cause
Remedy
Recovery
Receivable
Command
Command error
None
An undefined command or
undefined command parameter was
detected.
• The scanner ignores the incorrect
command or parameter. (Current
setting maintained)
• The scanner returns NACK and
waits for the next command
parameter.
The error condition is cleared when
the scanner receives a correct
command.
Fatal error
Red LED flashes in
sort interval.
• The lamp is dead.
• The main unit is faulty.
• Firmware downloading failed.
• Turn the lamp off and stop the
operation.
• Set Bit 7 of the status bit.
• Turn the scanner off and then back
on.
• Send the initialization command
(ESC@).
ESC F, ESC f,
ESC @
Summary of Contents for Perfection 4870 Photo
Page 1: ...EPSON Perfection4870Photo Color Image Scanner Service Manual SESC03 008 ...
Page 5: ...Revision Status Revision Date of Issue Description A December 10 2003 First release ...
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 19: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 29: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 37: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 63: ...C H A P T E R 5 ADJUSTMENT ...
Page 65: ...C H A P T E R 6 MAINTENANCE ...
Page 68: ...C H A P T E R 7 APPENDIX ...
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......