EPSON Perfection1200
Revision B
Disassembly and Assembly
Disassembly Procedures
38
6.
Remove the inverter lamp connector from the inverter board.
7.
Remove one black screw and a connector (2-pin) for CCD sensor board,
then remove the inverter board.
8.
Remove the inverter lamp from the upper cover.
Figure 4-9. Disassembly of the Carriage Unit (3)
Figure 4-10. Inverter Lamp Removal
C A U T I O N
When installing the inverter lamp, locate the wire as it is
shown in figures 4-9 and 4-10.
Inverter Board
Connector
Black screw
Connector (2-pin)
Upper Cover
Inverter Lamp
Inverter Board