3-4
Handling
Rev. A
Confidential
Storage Precautions
❏
Do not store the printer in environments with excessive dust, high temperature, high
humidity, or in direct sunlight.
❏
Before storing the EU-T532/T542 for an extended time, remove the paper and wipe off dirt
and dust; then clean parts such as the
platen
and the
thermal head
of the printer module,
rollers of the cut sheet presenter module with alcohol. After the alcohol evaporates, close
each module and store the unit.
Note:
If you leave the printer with the paper installed, discoloration of the paper and stickiness between the
paper and the
platen
may occur. In this case, replace the paper.
❏
Storing the printer for an extended period with the
platen
closed could cause the platen
rubber to deform and result in defective printing. If the platen rubber is deformed, it can be
restored to its proper shape by feeding paper through the printer. Just feed paper through
the printer until the
platen
works properly; then resume printing.
Opening/Closing Units and Modules
Note:
❏
Do not apply excessive pressure to any operation part; otherwise its function may be damaged because
of deformation or damage of the part.
❏
Apply pressure to each operation part only in the specified direction; otherwise its function may be
damaged because of deformation or damage of the part.
Paper Roll Supply Module
Opening/closing the paper roll hold unit (See Figure 3-2.)
1. Lift the
plate, fixed
upward (in the direction of arrow B) to release the lock with the
shaft,
paper roll
.
2. Pull the
plate, fixed
in the direction of arrow A to open the unit.
3. To close the unit, push it to the
shaft, paper roll
until it stops. At this time, make sure that
the
plate, fixed
is securely engaged with the groove on the
shaft, paper roll
. (Make sure
the unit is not open when it is pulled in the direction of arrow A.)
Printer Module
Opening/closing the platen unit (See Figure 3-2.)
1. Turn the
lever, platen
(green lever) of the printer module in the direction of arrow C to
open the unit.
2. To close the unit, turn the
lever, platen
in the direction of arrow D.