E0C6001 TECHNICAL HARDWARE
I-62
6.4 Analog Circuit Characteristics and Power Current Con-
sumption
E0C6001 (Normal Operating Mode)
Unless otherwise specified
V
DD
=0 V, V
SS
=-3.0 V, fosc=32.768 kHz (crystal oscillation), Ta=25°C, C
G
=25 pF,
V
S1
, V
L1
, V
L2
and V
L3
are internal voltages, and C
1
=C
2
=C
3
=C
4
=C
5
=0.1 µF
E0C6001 (Heavy Load Protection Mode)
Unless otherwise specified
V
DD
=0 V, V
SS
=-3.0 V, fosc=32.768 kHz (crystal oscillation), Ta=25°C, C
G
=25 pF,
V
S1
, V
L1
, V
L2
and V
L3
are internal voltages, and C
1
=C
2
=C
3
=C
4
=C
5
=0.1 µF
Item
Internal voltage
Power current
consumption
Symbol
V
L1
V
L2
V
L3
I
OP
Condition
Connect 1M
Ω
load resistor between V
DD
and V
L1
(without panel load)
Connect 1M
Ω
load resistor between V
DD
and V
L2
(without panel load)
Connect 1M
Ω
load resistor between V
DD
and V
L3
(without panel load)
Min
1/2•V
L2
-0.1
3/2•V
L2
-0.1
Typ
V
SS
1.0
2.5
Unit
V
V
V
µ
A
µ
A
Max
1/2•V
L2
×
0.9
3/2•V
L2
×
0.9
2.5
5.0
During HALT
During execution
Without panel load
Item
Internal voltage
Power current
consumption
Symbol
V
L1
V
L2
V
L3
I
OP
Condition
Connect 1M
Ω
load resistor between V
DD
and V
L1
(without panel load)
Connect 1M
Ω
load resistor between V
DD
and V
L2
(without panel load)
Connect 1M
Ω
load resistor between V
DD
and V
L3
(without panel load)
Min
1/2•V
L2
-0.1
3/2•V
L2
-0.1
Typ
V
SS
2.0
5.5
Unit
V
V
V
µ
A
µ
A
Max
1/2•V
L2
×
0.85
3/2•V
L2
×
0.85
5.5
10.0
During HALT
During execution
Without panel load