E0C6001 TECHNICAL HARDWARE
I-50
Table 4.8.1 shows the control bits and their addresses for
the heavy load protection function.
Table 4.8.1 Control bits for heavy load protection function
Control of heavy
load protection
function
Heavy load protection mode on/off (0FAH D3)
When 1 is written: Heavy load protection mode on
When 0 is written: Heavy load protection mode off
Reading:
Valid
When HLMOD is set to 1, the IC enters the heavy load
protection mode.
In the heavy load protection mode, the consumed current
becomes larger. Unless necessary, do not select the heavy
load protection mode with the software.
HLMOD
Address
Comment
Register
D3
D2
D1
D0
Name
SR
1
0
0FAH
HLMOD
0
0
0
HLMOD
0
0
0
0
Heavy load protection mode register
R
R/W
Heavy
load
Normal
load