10. Insert the standard 250-sheet tray into the printer, and push until it stops.
Important:
Do not use excessive force on the tray. Doing so could damage the tray or the inside of the printer.
Replacing the Fuser Unit
This section describes how to replace the fuser unit.
c
Caution:
Before removing the fuser unit, turn off the printer and wait for 40 minutes until the fuser unit
cools down.
Important:
❏
To prevent electric shock, always turn off the printer and disconnect the power cord from the
grounded outlet before performing maintenance.
❏
Avoid bright light and try to finish the replacement within 5 minutes.
Removing the Fuser Unit
1. Turn off the printer and disconnect the power cord.
Epson AcuLaser CX29 Series User’s Guide
Maintenance
412