![Epoch WT-PP User Manual Download Page 12](http://html1.mh-extra.com/html/epoch/wt-pp/wt-pp_user-manual_2418062012.webp)
Contacts us : email :
, Ph: 080-23481364
Serial Communication Protocol
The communication protocols used are a) Request mode b) Dump mode c) Modbus RTU mode d)
Modbus ASCII mode
Note:
Modbus RTU mode implemented and tested with Simply modbus Software,
Modscan32,Modbus
tester.
Communication settings:
Parity :
None ;
Data Bits:
8 ;
Stop Bits: 1 ; Flow Control: None
Baud rate is settable under setup.
Request Mode:
If the Communication mode (C-nod), under setup is “rE9” then the below protocol will dump one
time based on the request from PC.
Baud rate is settable under setup.
For Error condition weight value,
Over Range (
OR)
Weight value is 99999.
Over Capacity (
OC)
Weight value is 88888.
Under Range (
UR)
Weight value is 77777.
Dump Mode:
If the Communication mode (C-nod), under setup is “dUmp” then the below protocol will dump
continuously (Same as request mode response).
Baud rate is settable under setup.
%XX[YZWWWWW]$