28
TROUBLESHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and
follow the steps listed. If further assistance is needed, please see the front cover of this manual.
PROBLEM: The power does not turn on
SOLUTION:
a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor
is plugged into a properly grounded outlet (see page 14). Use only a single-outlet surge suppres-
sor that meets all of the specifications described on page 14.
IMPORTANT: The treadmill is not
compatible with GFCI-equipped outlets.
b. After the power cord has been plugged in, make sure that the key is inserted into the console.
c. Check the power switch located on the treadmill frame
near the power cord. If the switch protrudes as shown,
the switch has tripped. To reset the switch, wait for five
minutes and then press the switch back in.
PROBLEM: The power turns off during use
SOLUTION:
a. Check the power switch (see the drawing above). If the switch has tripped, wait for five minutes
and then press the switch back in.
b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five
minutes, and then plug it back in.
c. Remove the key from the console. Reinsert the key into the console.
d. If the treadmill still will not run, please see the front cover of this manual.
PROBLEM: The console displays remain lit when you remove the key from the console
SOLUTION:
a. The console features a display demo mode, designed to be used if the treadmill is displayed in a
store. If the displays remain lit when you remove the key, the demo mode is turned on. To turn off
the demo mode, hold down the Stop button for a few seconds. If the displays are still lit, see THE
INFORMATION MODE on page 26 to turn off the demo mode.
PROBLEM: The displays of the console do not function properly
SOLUTION:
a. Remove the key from the console and
UNPLUG THE
POWER CORD.
Place the treadmill in the storage po-
sition (see HOW TO FOLD THE TREADMILL on page
27).
Next, remove the two indicated #8 x 3/4" Screws (7).
Tripped
Reset
c
a
7
7