Epever Tracer-AN Series User Manual Download Page 9

5

 

appear Multi-MPP, but in actually there is only one real Maximum Power Point. 
As the below Figure 1-3 shows: 

 

Figure 1-3 Mutil-MPP Curve 

If the program works improperly after appearing Multi-MPP, the system will not 
work on the real max. power point, which may waste most solar energy 
resources and seriously affect the normal operation of the system. The typical 
MPPT algorithm, designed by our company, can track the real MPP quickly 
and accurately, improve the utilization rate of the array and avoid the waste of 
resources. 

1.5 Battery Charging Stage 

The controller has a 3 stages battery charging algorithm (Bulk Charging, 
Constant Charging and Float Charging) for rapid, efficient, and safe battery 
charging. 

 

 

 

 

 

 

 

 

 

Figure 1-4 Battery changing stage 

Curve 

 

 

Summary of Contents for Tracer-AN Series

Page 1: ...Tracer AN series MPPT Solar Charge Controller User Manual Models Tracer8415AN Tracer10415AN...

Page 2: ......

Page 3: ...ide controller DO NOT disassemble or attempt to repair the controller Mount the controller indoors Avoid direct sunlight high temperatures and do not install in locations where water can enter the con...

Page 4: ...1 General Installation Notes 8 2 2 PV Array Requirements 8 2 3 Mounting 10 2 4 Wiring 11 2 5 Power Up 15 3 Operation 15 3 1 Indicator 16 3 2 Button Function 16 3 3 LCD Display 16 3 4 Battery Type 18...

Page 5: ...tor in various fields like telecommunication base station household system wilderness monitoring system etc All round electronic fault self test function and enhanced electronic protection function co...

Page 6: ...t 4 charging options Sealed Gel Flooded and User Battery temperature compensation function Real time energy statistics function With RS 485 communication bus interface and Modbus communication protoco...

Page 7: ...roller software via RS485 Connect for RBVS Remote Battery Voltage Sensor to detect accurate battery voltage 1 3 Maximum Power Point Tracking Technology Due to the nonlinear characteristics of solar ar...

Page 8: ...crepancy between IPV IBat The greater the discrepancy between array and battery the bigger reduction of the conversion efficiency of the system thus the controller s conversion efficiency is particula...

Page 9: ...lar energy resources and seriously affect the normal operation of the system The typical MPPT algorithm designed by our company can track the real MPP quickly and accurately improve the utilization ra...

Page 10: ...tion of battery box is recommended CAUTION Equipment damage Equalization may increase battery voltage high enough so as to damage sensitive DC loads Verify that all load allowable input voltages are 1...

Page 11: ...all the charge current transforms into heat and gas at this time Then the controller reduces the voltage to the floating stage charging with a smaller voltage and current It will reduce the temperatu...

Page 12: ...onnections and corroded wires may result in high heat that can melt wire insulation burn surrounding materials or even cause fire Ensure tight connections and use cable clamps to secure cables and pre...

Page 13: ...ging current will be limited within rated range therefore the controller will charge the battery with the rated charging power even if the input power at the PV exceeds The actual operation power of t...

Page 14: ...150W 12V 6300W 24V 9450W 36V 12600W 48V 150V 138V Tracer10415AN 100A 1325W 12V 2650W 24V 4000W 36V 5300W 48V 3975W 12V 7950W 24V 12000W 36V 15900W 48V At minimum operating environment temperature At 2...

Page 15: ...mobile applications be very certain that all wirings are connected securely Use cable clamps to prevent cables from swaying when the vehicle is in motion Unsecured cables create loose and resistive co...

Page 16: ...tion The battery voltage sensor connection is not required to operate the controller but it is recommended for the best performance The voltage sensor wires should be cut into the required length The...

Page 17: ...The battery wire size must conform to the rated current the reference size as below Model Rated charge current Battery wire size Tracer8415AN 80A 25mm 2 4AWG Tracer10415AN 100A 35mm 2 2AWG NOTE The wi...

Page 18: ...es of the rated current Keep OFF before connection Connect solar positive and negative to solar terminals on the controller in the figure 1 1 Please pay much attention to and Solar array short circuit...

Page 19: ...rray Turn on the battery Fuse firstly Observe if battery indicator light and startup interface work fine or not Refer to section 4 Always connect the battery firstly in order to allow the controller t...

Page 20: ...Flashing PV Over voltage Fault LED indicator Red OFF Normal Red Flashing Over discharged Battery Overheating All indicator is fast flashing System voltage error All indicator is slowly flashing Contr...

Page 21: ...level shows full battery frame blink fault icon blink Battery over temperature Battery level shows current value battery frame blink fault icon blink When load current reaches1 02 1 05 times 1 05 1 2...

Page 22: ...ge 13 2V 13 2V 13 2V 9 17V Low Voltage Reconnect Voltage 12 6V 12 6V 12 6V 9 17V Under Voltage Warning Reconnect Voltage 12 2V 12 2V 12 2V 9 17V Under Volt Warning Volt 12 0V 12 0V 12 0V 9 17V Low Vol...

Page 23: ...19 Discharging Limit Voltage e Boost Reconnect Charging voltage Low Voltage Disconnect Voltage CAUTION Please refer to user guide or contact with the sales for the detail of setting operation...

Page 24: ...ontroller will result Correct the miswire to resume normal operation Battery Over voltage When battery voltage reaches to the voltage set point of Over Voltage Disconnect Voltage the controller will s...

Page 25: ...tage is lower than 9V Please check the voltage of battery At least 9V voltage to activate the controller Fault LED indicator flashing Interface blink Battery voltage higher than over voltage disconnec...

Page 26: ...rm that all the system components are ground connected tightly and correctly Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten termi...

Page 27: ...6W Grounding Common Negative Max PV open circuit voltage must never exceed 138V under 25 conditions Environmental Parameters Environmental Tracer8415AN Tracer10415AN LCD temperature range 20 70 Ambien...

Page 28: ...urrent voltage or power exceeding the rated value of controller The controller is working temperature exceed the limit working environment temperature User disassembly or attempted repair the controll...

Page 29: ...25 Annex I Dimensions Tracer8415AN Dimensions Unit mm...

Page 30: ...26 Tracer10415AN Dimensions Unit mm Any changes without prior notice Version number V1 0...

Page 31: ......

Page 32: ...BEIJING EPSOLAR TECHNOLOGY CO LTD Tel 86 10 82894112 82894962 Fax 86 10 82894882 E mail info epsolarpv com Website http www epsolarpv com http www epever com...

Reviews: