10
When the PV array straight polarity, the actual operation of the PV array must
NOT exceed three times of rated charge power
;
When the PV array reverse
polarity, the actual operation must NOT exceed 1.5 times. For real application
please refer to the table below:
Model
Rated
Charge
Current
Rated Charge
Power
Max. PV
Array Power
Max. PV
open circuit
voltage
Tracer8415AN
80A
1050W/12V
2100W/24V
3150W/36V
4200W/48V
3150W/12V
6300W/24V
9450W/36V
12600W/48V
150V
①
138V
②
Tracer10415AN
100A
1325W/12V
2650W/24V
4000W/36V
5300W/48V
3975W/12V
7950W/24V
12000W/36V
15900W/48V
①
At minimum operating environment temperature
②
At 25
℃
environment temperature
2.3 Mounting
CAUTION:
When mounting the controller, ensure at least 150mm of
clearance above and below the controller for proper air flow. If
mounted in an enclosure, ensure good ventilation condition of the
box.
WARNING:
Risk of explosion!
Never install the controller with flooded batteries in a sealed
enclosure! Do not install the battery in a confined area where
battery gas can accumulate.