![Epever Tracer-AN Series User Manual Download Page 25](http://html1.mh-extra.com/html/epever/tracer-an-series/tracer-an-series_user-manual_2417327025.webp)
21
damaged from overcharging or over discharged.
Controller Overheating
If the temperature of the controller heat sinks exceeds 85
℃
, the controller will
automatically start the overheating protection and recover below 75
℃
.
High Voltage Transients
PV is protected against small high voltage surge. In lightning prone areas,
additional external suppression is recommended.
CAUTION:
Faults will be cleared every day, so the faults which
aren‟t caused by hardware can be solved intelligently.
4.2 Troubleshooting
Faults
Possible reasons
Troubleshooting
The LED&LCD is off
during daytime when
sunshine falls on PV
modules properly
PV array disconnection
Confirm that PV and battery wire
connections are correct and tight
Wire connection is
correct, LCD not display
Battery voltage is lower
than 9V
Please check the voltage of
battery. At least 9V voltage to
activate the controller
Fault LED indicator
flashing
Interface
blink
Battery voltage higher
than over voltage
disconnect voltage(OVD)
Check if the battery voltage is too
high, and disconnect the solar
module
Fault LED indicator
flashing
Interface
blink
Battery under voltage
Load output is normal, charging
LED indicator will return to green
automatically when fully charged
Charging and fault LED
indicator
flashing
Interface
blink
Battery over temperature
The controller will cut off the
output automatically, LED
indicator will return to green
automatically when fully charged
4.3 Maintenance
The following inspections and maintenance tasks are recommended at least
two times per year for best controller performance.
Make sure controller firmly installed in a clean and dry ambient.
Make sure no block on air-flow around the controller. Clear up any dirt and
fragments on radiator.