REV. 10/2019
3
F
Well place cables to avoid be damaged when you remove and install battery.
Installation is in the reverse order, pay attention on battery install position and cable
connection. Make sure to protect the cables to avoid damage when you install the battery.
WARNING
Daily maintenance
Please charge timely without any excessive discharging.
Maintain clean the surface of the storage battery.
The charging environment temperature shoulle be 5°C - 40°C.
Avoid the battery becoming corroded by water or corrosive liquid.
Keep the battery away from all fire sources,heat sources and flammable or explosivematerials.
Storage
We recommend that batteries are stored at a height between 60 and 120 cm.
Store the battery in a dry place at a temperaturebetween 0 and 40° to preserve its
service life. This area must not be hermetically sealed to allow air renewal;
In case of long-term storage of the storage battery, the supplementary charging should
be conducted for the battery once every two months, and charging quantity should be
proper but not full, namely maintaining the discharging depth at about 80%.