32
Operating Instructions - SBM-IR Modul
Operation
EN
3
Set the IR emitter intensity.
The value can be set in 2% intervals from 20% to 100%.
Only 0% or 100% may be selected for emitters at the IR-3 connection;
20%-100% for foils.
4
Confirm the set value.
The value is saved and the display returns to the screen for operating
mode selection.
The channel group emitters are immediately set to the new intensity.
This means they are not set to the target temperature.
5
Repeat steps
to
for the next channel.
3.4.6 Switching hysteresis for the IR temperature
In the service settings, you can also set a temperature range within which
the IR emitters are switched on and off. It applies to all connected IR emit-
ters.
Example — 46°C target temperature and hysteresis 4 K:
The IR emitter is
switched off at 48°C and switched on at 44°C.
IR intensity (A)
Setting
IR intensity
09:06
66%