background image

1

Druck Nr. 29342787en /  - 22.06

Installation and user's manual

ECON H1

IP x4

GB

Summary of Contents for ECON H1

Page 1: ...1 Druck Nr 29342787en 22 06 Installation and user s manual ECON H1 IP x4 GB...

Page 2: ...le through connection to circuit breakers Heating time shut off 6 h or optionally 12 h after removal of resistance Display two digit 7 segmented display Protection type IPx4 in accordance with DIN Ger...

Page 3: ...r sauna ovens up to 9 kW Up to 36 kW when combined with a breaking capacitor l Completely disconnect the control unit from the electrical circuit i e flip all circuit breakers or the main circuit brea...

Page 4: ...luded spacer tubes as shown in Illust 3 3 3 3 Illust 3 3 Illust 3 2 Illust 3 1 15 cm ca 34 cm 20 cm ca 20 cm Illust 2 Illust 4 lead hole for oven connector lead hole for vaporizer connector lead hole...

Page 5: ...ntrol unit Warning Always connect the sauna oven s neutral conductor During steam operation one of the phases shuts down therefore the heat doesn t spread evenly In consequence the neutral conductor b...

Page 6: ...amp must be splashproof by Standard IP54 and suitable for temperatures up to 140 C The sauna lamp can be mounted anywhere except in the area of the rising hot air above the oven 2 3 Connecting the sen...

Page 7: ...now be interrupted Illust 12 LED display heating red display for humidity level LED display operational green button for decreasing value button for CLIMA mode temperature selection function selection...

Page 8: ...ight up Depending on the current temperature in the sauna cabin the sauna oven s red operational display will light up signaling the oven is heating Use the right hand dial to set the desired cabin te...

Page 9: ...r up to 8 liters depending on the model will be heated more rapidly When the oven and vaporizer are optimally adjusted to the sauna cabin the values for humidity given in Illust 15 can be reached at 1...

Page 10: ...zzer providing an acoustical signal as an additional warning when the thermostat in the vaporizer registers a water deficit 4 Troubleshooting Unit cannot be put in operation mode Check to see whether...

Page 11: ...rature An important value is the resistance at nor mal room temperature At 20 C this is about 1 9 k To determine the temperature on the temperature sensor you can measure the low voltage on the sensor...

Page 12: ...ration or handling through non authorized persons are not covered under the terms of warranty In the event of a claim please indicate the serial number as well as the article code number and type name...

Reviews: