background image

Service Address:

EOS Saunatechnik GmbH
Schneiderstriesch 1

35759 Driedorf, Germany

Tel: +49 (0)2775 82-514
Fax: +49 (0)2775 82-431

[email protected]
www.eos-sauna.de

WARRANTY

The warranty is provided according to the legal 
regulations at present.

Manufacturer’s guarantee:

• 

The period of guarantee starts from the date 
of purchase and lasts up to 2 years by com-
mercial use and 3 years by private use.

• 

Always  include  the  completed  guarantee 
certifi cate when returning equipment.

• 

The guarantee is void for appliances which 
have been modifi ed without manufacturer’s 
explicit agreement.

• 

Damages  caused  by  incorrect  operation  or 
handling  through  non-authorized  persons 
are not covered under the terms of guaran-
tee.

• 

In  the  event  of  a  claim  please  indicate  the 
serial  number  as  well  as  the  item  number 
and  model  name  with  detailed  description 
of the fault.

• 

This  guarantee  covers  defective  parts  and 
labour but not the defects caused by wear 
and tear.

In  case  of  complaint  please  return  the  equip-
ment in its original packaging or other suitable 
packaging (caution: danger of transport dam-
age) to our service department.

Always include the completed warranty certifi -
cate when returning equipment.

Possible shipping costs arising from the trans-
port to and from point of repair cannot be over-
taken by us.

Outside  of  Germany  please  contact  your  spe-
cialist dealer in case of warranty claims. Direct 
warranty  processing  with  our  service  depart-
ment is in this case not possible. 

Equipment commissioning date:

Stamp  and  signature  of  the  authorized  elec-
trician:

Please keep this address in a safe place togeth-
er with the installation guide.

To help us answer your questions quickly and 
competently  please  provide  the  information 
printed on the type shield including the model, 
item no. and serial no., in all inquiries.

30

GB

Summary of Contents for ECON D1

Page 1: ...1 D IP x4 Made in Germany ECON D1 Druck Nr 29344711en 23 15 GB Installation and operating instruction sauna control unit...

Page 2: ...or 10 Electrical connection 12 Connecting the sauna heater 12 Connecting the sauna lamp 12 Installation diagram 13 Terminal arrangement on the circuit board 13 Connecting the sauna heater 14 Operation...

Page 3: ...Switching on the sauna unit with Life Guard 22 Individual settings 23 Cabin temperature 23 Auto Stop 24 Life Guard 25 Unit fuses 27 Error messages 28 The device switch Switch off 29 Service Address 30...

Page 4: ...rature protection fuse Technical data Nominal voltage 400 V 3 N 50 Hz AC Switching capacity max 9 kW ohmic load AC1 operation Heating time limitation 6 h Display LCD display 40 x 22 mm alphanumeric wi...

Page 5: ...ods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please observe th...

Page 6: ...e the dimensions in the assem blyinstructions especiallywheninstalling the temperature sensor The temperature above the oven is critical for the temper ature setting The temperature can be held within...

Page 7: ...ialist of an authorized electric shop We would like to draw your attention that in case of a warranty claim you are kindly requested to present a copy of the invoice of the executive electric shop Whe...

Page 8: ...hole The control unit is hooked onto this screw Therefore leave the screw out by approx 3 mm Fig 3 2 3 Hook the control unit onto the 3 mm protru ding screw in the upper mounting hole Insert the supp...

Page 9: ...east 3 5 cm deep according to the dimension in Fig 5 Insert the supplied rubber grommets into the openings at the rear wall of the housing and insert the connecting cables through these openings Place...

Page 10: ...oven sensor in cabins up to 2 x 2m according to Illust 7 and 8 in larger cabins according to Illust 7 and 9 20 cm Fig 7 Housing Red Red Sensor circuit board Sensor white Limiter white Limiter Illust 1...

Page 11: ...t the line for overtemperature protection must be checked for short circuits In order to do this disconnect one of the wires of the white ca ble in the sensor casing The respective error message appea...

Page 12: ...nt of the air intake according to the manufacturer s installation in structions Run the silicone line through the ductwork to the power unit and connect it to the appropri ate terminals as directed in...

Page 13: ...13 GB Installation diagram 3 5 4 5 400 V 3 N AC 50 Hz ECON X2 F2 F1 L1 L2 L3 N W V U N N L Terminal arrangement on the circuit board Plug for sensor connection...

Page 14: ...cting the sauna heater 400 V 3 N AC 50 Hz max 100 W X1 ECON P max 9 kW U V W N L1 L2 L3 N 142 C KTY 10 5 Sensor Limiter wei white rot red X2 N L Warning Always connect the neutral conductor N of the s...

Page 15: ...you can put your sauna unit into operation Over the following pages we will show you the options provided to you with the control The user interface Operating buttons Cabin lighting on off Heating on...

Page 16: ...ing phase the thermometer fills up on the right side of the display Energy saving display 12 34 12 00 5 59 Auto stop Current time The clock symbol The light symbol when the light is switched on 12 00...

Page 17: ...r change is made 12 00 30 C Temperature Modifiable parameter 12 00 30 C Temperature If no key is pressed for 15 s the unit switches back into the default display Changes made up to then are not saved...

Page 18: ...ommissioning 12 00 DE GB NL PL I RU 12 00 0 00 0 00 Time of day 12 00 DE GB NL PL I RU 12 00 12 00 Time of day 12 00 12 00 Time of day 12 00 12 30 Time of day 12 00 Life Guard 3 s 3 s 3 s 12 00 12 30...

Page 19: ...time 12 00 DE GB NL PL I RU 12 00 DE GB NL PL I RU 12 00 DE GB NL PL I RU 12 00 12 30 Time of day 3 s 12 00 12 30 Time of day 12 00 30 C Temperature MODE MODE MODE MODE 12 00 12 30 Time of day 12 00 1...

Page 20: ...ort time e g 20 minutes after which the sauna unit is switched off except for the cabin lighting Af ter this time has elapsed the unit can be MODE switched on again by pushing the button for the set t...

Page 21: ...em can still be switched off in operation 12 00 30 C Temperature 3 s 12 00 30 C Temperature 12 00 30 C Temperature Activate Stand by Operation Deactivate 12 00 30 C Temperature 3 s 12 00 30 C Temperat...

Page 22: ...nction Life Guard 12 00 14 min Life Guard MODE After expiration of the Life Guard time the sauna heater is switched off and the set Life Guard time blinks Restart MODE or switch off the system 3 s 12...

Page 23: ...Temperature MODE 12 00 85 C Temperature Setting range Finnish mode 30 115 C 12 00 85 C Temperature 3 s 12 00 30 C Temperature MODE Hereafter we are showing you options that allow you to adjust the co...

Page 24: ...xpired The time is adjustable from 0 01 to 6 00 hours 12 00 30 C Temperature 12 00 6 00 Auto stop MODE In Stand by In operation 12 00 6 00 Auto stop 12 00 30 C Temperature 12 00 6 00 Auto stop 12 00 3...

Page 25: ...25 GB 12 00 3 30 Auto stop 3 s MODE 12 00 3 30 Auto stop 15 s 3 s MODE 12 00 30 C Temperature 3 s 12 00 30 C Temperature 12 00 3 30 Auto stop 12 00 30 C Temperature...

Page 26: ...ife Guard MODE Here you can set after what time the sauna unit is switched off and by pushing the MODE button again you can restart the Life Guard time This setting can only be selected in Stand by wh...

Page 27: ...1 L1 L2 L3 N W V U N N L F1 F2 Unit fuses F1 T 2A Fuse electronics primary and light and fan F2 T 315 mA Fuse of the electronics secondary Load board D1 Control board Only allow a specialist to carry...

Page 28: ...erature sensor PTC is faulty or the line to the temperature sensor has a short circuit interrupted limiter circuit The temperature fuse 142 C has triggered or the line to the temperature fuse is inter...

Page 29: ...s using this switch To turn the light on in the cabin while the unit is still disconnected push the left side of the ro cker to the second latch switch setting II Tomaketheunitreadyforoperation switch...

Page 30: ...el name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equip ment in its ori...

Page 31: ...p ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall accept no liability for damage incu...