EONE Dilution SOLUTIONS MDE0110MF.75KIT Manual Download Page 10

8

Push the right arrow until the display reads 

OPERATING MODE/ 1 x N (M) MODE.  

Please see page 9 for detailed instructions to 

determine the Number of Pulses (N) Per Water 

Meter Signal.

Pulse/Stroke Volume

 is calculated in relation to 

the  pressure  in  the  irrigation  line.  Use  the  values            

below to determine volume.

Push the down arrow to enter into the program.
Use the right arrow button to enter number of 

pulses for each gallon of water. Press the down 

arrow to save the settings.

           Push the 

START/STOP

 button to begin the  

           program operation.

           You can now turn on the irrigation water to begin   

           operation of the system using the water meter.  

7

8

9

10

See operating manual for complete 

instructions and safety standards. 

When connecting a metering pump either to a 

public water supply or to its own water source, 

you must respect the regulations in force 

concerning protection of the source 

i.e. backflow prevention, etc. 

!

CAUTION

Micro-Doser Kit Installation

NEED HELP? CALL 1-800-451-6628

PUMP 

MODEL

PSI

Single Pulse 

Volume (mL)

Maximum 

Volume (mL)

0110

30

0.23

41.4

35

0.22

39.6

40

0.22

39.6

45

0.21

37.8

50

0.21

37.8

55

0.20

36

60

0.19

34.2

65

0.19

34.2

70

0.18

32.4

Pump Programming

11

Summary of Contents for Dilution SOLUTIONS MDE0110MF.75KIT

Page 1: ...eOne eOne 3 4 MICRO DOSER KIT Item MDE0110MF 75KIT MANUAL Scan this QR code for digital instructions and support videos...

Page 2: ...Check Valve CV34 PH 1 Tee TT34 1 to Reducer Bushing RB75 50ET 1 Close Nipple NIP075 2 3 Thread Tape TEF12 1 Digital Instructions and Support Videos QR Tag TAG MD 1 Included in the MicroDoser Kit Micr...

Page 3: ...rt Item Number Qty Part Image Pressure Relief Anti Siphon Valve Assembled Kit 4x6 with Wall Bracket PRV4X6 1 Syringe Kit 07944 KIT 1 D Included for difficult priming situations only NOTE Parts ordered...

Page 4: ...the Nut Wrap Thread Tape 4 to 5 times on all threads except on the PRV Adapter Kit parts Make sure to wrap tape clockwise to prevent from unraveling Attach a Union to the inlet side of the Water Mete...

Page 5: ...e sure the arrow on the Mixing Chamber points in the direction of the flow Insert the third Close Nipple in the outlet of the Mixing Chamber and attach the last Union to the other side of the Close Ni...

Page 6: ...hort the tension may cause leaks Connect each one of the tube s halves to the Adapters on the PRV see Steps 14 15 To attach the tubes to the PRV insert the tube through the outside opening of PRV Nut...

Page 7: ...he valve to the threads level see image Insert the Injection Valve into the Reducer Bushing at the top of the Tee in the Micro Doser Plumbing Assembly hand tighten only Anchor the Micro Doser Plumbing...

Page 8: ...e chemical container Next connect the pump to the Water Meter see steps 26 31 below CONNECTING THE WATER METER You will need a punch and a small flat head screwdriver To connect the pump to the Water...

Page 9: ...the air bleed nut Push the START STOP button to begin the priming functions The pump will begin to stroke click Once the chemical starts going down the air bleed tube re tighten the air bleed nut bac...

Page 10: ...TART STOP button to begin the program operation You can now turn on the irrigation water to begin operation of the system using the water meter 7 8 9 10 See operating manual for complete instructions...

Page 11: ...desired injection will be minimal but fluctuations may be noticeable at very low or very high flow rates See USING THE PRESSURE RELIEF VALVE to decrease the Single Pulse Volume to a volume that divide...

Page 12: ...IC TESTING PROCEDURE steps Repeat steps 3 4 as necessary until desired Single Pulse Volume is reached 1 2 3 4 5 Black Protection Cap Counter Nut Adjustment Screw Volumetric Testing Procedure You can t...

Page 13: ...e Mode Settings Press button the screen should read PULSES MINUTE PULSES NUM 300 Press buttons to set PULSES MINUTE to 100 100 pulses min Press the button to save the new PULSE MINUTE settings Open Te...

Page 14: ...iner from the graduated cylinder and place the suction strainer back in the concentrate container Return concentrate solution remaining in graduated cylinder to concentrate container to eliminate wast...

Page 15: ...ight from impacting nutrient rich water eliminating the potential for biofilm and algae growth in the chamber Now attach the QR Code tag included to the Micro Doser installation as shown The QR Code o...

Page 16: ...Dilution Solutions 2090 Sunnydale Blvd Clearwater FL USA 1 800 451 6628 727 451 1198 www dilutionsolutions com...

Reviews: