www.enware.com.au
Call 1300 369 27
9
flow adjustment
BOTTLE FILLER
Adjusting water flow rate (2 L/min - 7 L/min):
1. Unscrew and remove the regulator screw
cover cap using a slotted screw driver.
(Note this is only a cover - the regulator
screw is inside once the cover is removed.)
2. Locate the regulator screw inside. Turn the
spring action handle on full and adjust the
screw - tighten to reduce the flow or loosen
to increase the flow.
3. Once the desired water flow is achieved, put
the cover cap back on.
-
+
Regulator
screw
inside
Cover cap
Regulator Screw
Location
HEX DRESS NUT
(892537)
PUSH BUTTON
CARTRIDGE
RETAINING NUT
CARTRIDGE
(BUB294)
SPOUT
BODY
TYPE 61 SPANNER FOR CARTRIDGE RETAINING NUT (892530)
INLET SCREEN MESH (892531)
FLOW ADJUSTMENT
SCREW
BUBBLER
Adjusting water stream height:
1. Unscrew hex cover nut from bubbler
body using a spanner. The nut and
push button can be removed to reveal
the top of the spring cartridge and the
cartridge locking ring.
2. Locate the flow adjustment screw in
the top of the cartridge. While pressing
the cartridge to fully on position, using
a small slotted screwdriver, screw the
adjustment screw in to reduce stream
height, or out to increase stream height.
3. Replace the push button and hex cover
nut and tighten.
4. Re-test bubbler fountain for correct
operation.