Operations Manual
OPERATION MODES, INFOS, ALERTS AND
RAP e2 container
8.
OPERATION MODES, INFOS, ALERTS AND ALARMS
8.1
OPERATION MODES
The following operation modes exist:
8.1.1
COOLING POWERSTEP X
• The container uses four different power steps for cooling, 1-4, depending on the required
cooling performance. "Cool Pow 1" is the lowest power step for cooling and "Cool Pow 4" is
the highest (i.e. maximum cooling).
• When the container has been cooling and there is no need for further cooling the power step
"Cool Pow 0" is displayed. At this power step there is no cooling (or heating) but the air
inside the cargo area continues to be circulated.
8.1.2
HEATING POWERSTEP X
• The container uses two different power steps for heating, 1-2, depending on the required
heating performance. "Heat Pow 1" is the lowest power step for heating and "Heat Pow 2" is
the highest (i.e. maximum heating).
• When the container has been heating and there is no need for further heating the power step
"Heat Pow 0" is displayed. At this power step there is no heating (or cooling) but the air
inside the cargo area continues to be circulated.
8.1.3
DEFROSTING POWERSTEP 2
• The container uses one power step, "Defrost Pow 2", for defrosting. At this power step the
cooling system is shut down for a few minutes for defrosting of evaporator. The defrosting
process does not affect the air temperature in the cargo space.