Operations Manual
RAP e2 container
7.2
SETTING TEMPERATURE
The recommended procedure is:
1.
To change between Celsius and Fahrenheit:
• Press
to enter the main menu; the display shows ”TEMP MENU“.
• Press
to enter the ”TEMP MENU“; the display shows ”SET TEMP“.
• Use
or
to step to ”Current unit F Set changes to C“ or
”Current unit C Set changes to F“(depending on current setting).
• Press
to confirm the change.
• Press
to return to default mode.
2.
Press
to enter the main menu; the display shows ”TEMP MENU“.
3.
Press
to enter the ”TEMP MENU“; the display shows ”SET TEMP“.
4.
Press
to enter the ”SET TEMP“; the display shows ”SET NEW TEMP“.
NOTE!
The ”SET NEW TEMP“ mode is activated for 30 seconds. If the display returns to default
mode before new set temperature has been confirmed by pressing
, the new container set
temperature was not saved.
5.
Use
and
to change the container set temperature.
Hold down the buttons to speed up the change.
6.
Press
to confirm the new container set temperature.
7.
Press
to return to default mode.
8.
Check that the container set temperature is correct in the default mode.
7.3
CHECKING OPERATION MODE
The recommended procedure is:
1.
Press
to enter the main menu; the display shows ”TEMP MENU“.
2.
Use
or
button to step to ”SYSTEM MENU“ and press
to confirm; the display
shows ”ALARM VIEW“.
3.
Use
or
button to step to ”OPER. MODE“ and press
to confirm.
4.
Check current operation mode.
Refer to chapter 8. Operation Modes, Infos, Alerts and Alarms
.
5.
Press
twice to return to default mode.