OWNER’S MANUAL

 

 

MODEL EPFX DM900 

WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH 

ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER 

 

IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT 

READ AND SAVE THESE INSTRUCTIONS 

 

 

 

 

 

 

 

 

 

Features 

 

 

Long-life, 99.97% HEPA (High Efficiency Particulate Air) Media Filter  

removes particles 0.3 micron and larger 

 

Carbon Prefilter removes lint and large particles, to extend life of HEPA Filter 

 

Two High Output Ultraviolet Germicidal Lamps 

 

CinQuartz™ Photo Catalytic Oxidation Filter removes unpleasant odors 

and Volatile Organic Compounds 

 

Carbon/ Potassium Permanganate Final Filter removes non-organic gases 

 

Kills or inhibits bacteria, viruses, mold, fungi and microbial growth 

 

Easy-to-change Filters and Lamps 

 

Powerful motor delivers up to 250 CFM (Variable Speed) of clean, sterilized air 

 

Heavy gauge galvanized steel cabinet and external powder-coat paint finish provides rigid 

installation and durability 

 

Plug-in Power Cord provides easy electrical connection 

 

Versatile installation can be duct mounted, collar mounted or used as stand alone unit. 

Stands with or without wheels optional 

 

FOR TECHNICAL SUPPORT AND REPLACEMENT FILTERS CALL:  1-866-998-9909 

[email protected] 

Summary of Contents for EPFX DM900

Page 1: ...moves unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits bacteria viruses mold fungi and microbial growth Easy to ch...

Page 2: ...a healthier more comfortable environment year round HOW IT WORKS Millions of airborne pollutants are carried through the return air ducts of the heating cooling system The Air Cleaner has been designe...

Page 3: ...e unit if you are duct mounting the Air Cleaner Bend all the flaps outward slightly less than 90 degrees except for the upper bottom flap which is only bent up 45 degrees This bottom flap will act as...

Page 4: ...ad of the clean exhaust air that will be returned to the duct from the Air Cleaner An 8 inch collar will be installed on the return duct and a length of 8 inch flexible hose or duct is required to att...

Page 5: ...astic bag and discard with regular household trash 3 Remove the plastic from the new filters before installing Discard plastic safely Take care not to damage the filters Hold by the filter frame only...

Page 6: ...tly pulling away from the reflector 4 Before replacing the lamps the reflector should be cleaned with a soft cloth and mild non abrasive soap 5 Replace the support clips by pressing them into the hole...

Page 7: ...put Voltage 120 V 60 Hz Power Consumption 200 Watts Air Flow EADM900UV VO A EADM900UV VO VS Variable Speed 250 CFM up to 250 CFM 424 8 m hr up to 424 8 m hr Cabinet 22 gauge Power Cord 9 0 ft 2 74 m F...

Page 8: ...or handling of either defective parts or replacement parts LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period...

Page 9: ...es odeurs d sagr ables et les compos s organiques volatiles Filtre final au permanganate de potassium et au charbon limine les gaz non organiques D truit ou limine les bact ries les virus la moisissur...

Page 10: ...s les peintures les vernis les produits d entretien personnel le mobilier en agglom r et bien plus encore Aide r duire le temps de nettoyage et l entretien et les co ts de red coration Offre un enviro...

Page 11: ...b qu 45 degr s Ce rabat servira de d flecteur pour l air qui revient dans le pl num 5 Placer les joints autour des deux ouvertures arri re du purificateur d air 6 Placer l unit sur le pl num pour que...

Page 12: ...tre mont de la m me mani re au bas de l unit Un collet de 8 pouces sera install sur le conduit de retour pr s de la fournaise et une longueur de 8 pouces de flexible ou de conduit est requis pour reli...

Page 13: ...lastique Prendre soin de ne pas endommager les filtres Tenir le filtre uniquement par son cadre 4 Indiquer la date de remplacement du filtre dans l espace pr vu 5 Placer les filtres dans leur rainure...

Page 14: ...pport en les pin ant dans le trou du r flecteur 6 Ne JAMAIS utiliser des lampes autres que celles fournies par le fabricant d origine Ne JAMAIS utiliser le purificateur d air avec une seule lampe 7 Lo...

Page 15: ...tiliser des gants jetables Recueillir les fragments l aide de papier ou de carton robuste Placer les fragments dans un sac en plastique Essuyer l endroit avec des serviettes en papier humides et place...

Page 16: ...entes limit es dans leur dur e la p riode pour laquelle la garantie limit e est fournie Les garanties explicites faites dans cette garantie sont exclusives et ne peuvent tre modifi es agrandies ou cha...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...PLASTIC PACKAGING ON INSIDE FILTERS ENLEVER LA PELLICULE DE PLASTIQUE DES FILTRES REFER TO OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS VOIR LES DIRECTIVES DANS LE MANUEL D INSTALLATION QUESTIONS DES...