FIELD INSTALLATION INSTRUCTION CHP12 PISTON/ORIFICE
Lagging holes positioned 8” on center for optional mounting
(FCP/FHP) DIMENSIONS AND SPECIFICATIONS
Continued
Connection K.O.s for Open Fresh Air
FHP 36- 48 Motorized Damper and
Power Assisted Fresh Air (4 Fan Type)
Wall Box Dimensions: 14”
(from finished floor level) x 32” wide x 8” deep
FHP 09- 30 Motorized Damper and
Power Assisted Fresh Air (2 Fan Type)
Wall Box Dimensions: 14”
(from finished floor level) x 17” wide x 8” deep
Model #
Air Handler
Condenser
Btuh
Factory Installed
Field Changeover
Part #
Piston/Orifice
Piston/Orifice
Size
Part #
Piston/Orifice
Piston/Orifice
Size
CHP12
9,000
240004064
.044”
240000727
.041”
12,000
NO CHANGE
NOTE:
Replace the existing piston (before installing
the unit) with the piston supplied in Kit Bag when
matching a:
• CHP12 with 9,000 Btuh Condenser
(See chart below)
APPLIES TO CHP 9,000 BTUH - 12,000 BTUH
Built After 4/05
Evaporator
PROPER INSTALLATION OF PISTON/ORIFICE REPLACEMENT