ELECTRICAL CONNECTIONS
EXCLAMATION-CIRCLE
CAUTION
Your Enviroheat system is equipped with a 10 Amp plug and cord that enables
connection to power via a weatherproof power outlet.
Electrical Protection Precautions
EXCLAMATION-CIRCLE
CAUTION
For safe performance this water heater is fitted with a thermostat and an over temperature cut-out.
These devices should not
be tampered with or removed.
Do not operate this water heater without the electrical thermostat and over temperature cut-out in the circuit.
Electrical connection of water heaters should be performed by a qualified person in accordance with AS3000 including any
current revisions.
COMMISSIONING CHECK LIST
System Location — ensure that
F
The location where the base of the water heater is located is sufficiently compact
to avoid subsidence when the system is filled with water.
F
Enough room has been allowed for service and maintenance of the water heater.
F
The system has been installed in a location that allows enough ventilation.
F
The location is free from any corrosive materials or chemicals.
F
The location is free from any excessive dust or material that can become airborne.
Water System Piping
F
Temperature and pressure relief valve (PTR) is properly installed with a discharge pipe plumbed to suitable drain.
F
Check that all plumbing connections including piping, valves and fittings are properly installed and free of leaks.
F
The system is completely filled with water and all air is drained from the tank and piping.
F
The tempering valve has been installed per manufacturer’s instructions and the
output water temperature is in the range required by local authorities.
F
The condensate drain line is installed and plumbed to suitable drain.
F
All hot water lines are appropriately insulated and protected from UV degradation.
Electrical Connections
F
The water heater is connected to a supply that has a voltage between 220-240 VAC.
F
All hard wiring complies with all local applicable codes and the requirements of this guide.
F
The water heater and electrical supply are properly grounded.
F
A correctly sized overload protection device has been installed.